"manufacturer": "ZVIDAR",
"manufacturerId": "0x045a",
"label": "WM25L",
"description": "Smartwings Smart Motor",
"devices": [
{
"productType": "0x0004",
"productId": "0x050b"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
},
"2": {
"label": "On/Off Control",
"maxNodes": 5
},
"3": {
"label": "Multilevel Set",
"maxNodes": 5
},
"4": {
"label": "Multilevel Start/Stop",
"maxNodes": 5
}
},
"paramInformation": [
{
"#": "1",
"label": "Enable Manual Pull-Start",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Close",
"value": 0
},
{
"label": "Open",
"value": 1
}
]
},
{
"#": "2",
"label": "Set Motor Direction",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Forward",
"value": 1
},
{
"label": "Reverse",
"value": 2
}
]
},
{
"#": "3",
"label": "Manually Set Open Borders",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Cancel",
"value": 0
},
{
"label": "Start",
"value": 1
}
]
},
{
"#": "4",
"label": "Manually Set Close Borders",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Cancel",
"value": 0
},
{
"label": "Start",
"value": 1
}
]
},
{
"#": "5",
"label": "Set Motor Status",
"valueSize": 1,
"defaultValue": 3,
"allowManualEntry": false,
"options": [
{
"label": "Open (Up)",
"value": 1
},
{
"label": "Close (Down)",
"value": 2
},
{
"label": "Stop",
"value": 3
}
]
},
{
"#": "6",
"label": "Calibrate Travel Point",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Up travel point",
"value": 1
},
{
"label": "Down travel point",
"value": 2
},
{
"label": "Third travel point",
"value": 3
}
]
},
{
"#": "7",
"label": "Delete Travel Point",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Delete all travel",
"value": 0
},
{
"label": "Delete up travel",
"value": 1
},
{
"label": "Delete down travel",
"value": 2
},
{
"label": "Delete third travel",
"value": 3
}
]
},
{
"#": "8",
"label": "Low Battery Level Alarm Threshold",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 50,
"defaultValue": 10
},
{
"#": "9",
"label": "Battery Auto Report Interval Time",
"valueSize": 4,
"unit": "seconds",
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 3600
},
{
"#": "10",
"label": "Battery Change Report Threshold",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 50,
"defaultValue": 5
},
{
"#": "11",
"label": "Curtain Status Report Command Setting",
"valueSize": 1,
"defaultValue": 6,
"allowManualEntry": false,
"options": [
{
"label": "Send nothing",
"value": 0
},
{
"label": "Send Basic Report",
"value": 1
},
{
"label": "Send Multilevel Switch Report",
"value": 2
},
{
"label": "Send window covering report",
"value": 3
},
{
"label": "Send Basic Report and Multilevel Switch Report",
"value": 4
},
{
"label": "Send Basic Report and window covering report",
"value": 5
},
{
"label": "Send Multilevel Switch Report and window covering report",
"value": 6
},
{
"label": "Send Basic Report and Multilevel Switch Report and window covering report",
"value": 7
}
]
}
],
"metadata": {
"inclusion": "Follow the user guide of hub to enter inclusion mode.\nPress and hold the Config Button more than 6s, enter Include Mode",
"exclusion": "Follow the user guide of hub to enter exclusion mode.\nPress and hold the Config Button more than 6s, enter Exclusion Mode",
"reset": "Press and hold the Config Button more than 10s. The Curtain will reset itself to factory default by sending a Device Reset Locally Notification to gateway when the button is released.\nNote:Please use this procedure only when the network primary controller is missing or otherwise inoperable"
}
}