Toolbox for creating (color) vision experiments. It provides a library and tools with the aim to create simple visual experiments on color-calibrated monitors.
Dependencies:
- OpenGL (e.g. mesa)
- OpenGL Mathematics
- glew
- HDF5
- C/C++ Minpack
- OpenBLAS
- LAPACK
- yaml cpp
- freetype
- cmake
- ninja (if you wanna build with ninja)
Install dependencies in Fedora:
dnf install glm-devel hdf5-devel cminpack-devel openblas-devel \
yaml-cpp-devel hdf5-devel libglvnd-devel \
freetype-devel cmake ninja-build
Configuring and building:
mkdir build
cd build
cmake -DCMAKE_BUILD_TYPE=Release -DCMAKE_INSTALL_PREFIX:PATH=/usr -G Ninja ..
ninja
Command | Description |
---|---|
pr655 |
interface with the PR655 spectrometer |
iris-measure |
use calibration stimuli to measure spectra |
iris-calibrate |
use measured spectra to generated calibration |
iris-cgen |
generate color (-r, -g, -b ) or white (-w ) stimuli, in |
increments of N steps (-N ) that repeat for (-B ) blocks |
|
iris-info |
Show information about known monitors |
iris-store |
Show store information |
iris-colorcircle |
Display a (calibrated) colorcircle |
iris-board |
Display an animated (and color calibrated checkerboard |
iris-isoslant |
Measure iso-slant data for a single test subject |
iris-fitiso |
Use iso-slant data to generate per-subject calibration |
The fundamental idea of IRIS is to present stimuli on a display (iris::data::display
)
which is the virtual entity composed of the following concrete entities:
- physical monitor (
iris::data::monitor
) - concrete settings of the monitor (brightness, contrast, …; represented by
iris::data::settings
) - graphics card output (HMDI, DisplayPort)
- the mode of the monitor (resolution, color depth, …; represented by
iris::data::monitor::mode
) - the graphics subsystem being used (currently only OpenGL)
The link between graphics card, monitor and graphics subsystem is configured via iris::data::link
.
To be able to use color accurately (in DKL space) a display needs to have valid calibration, i.e.
iris::data::rgb2lms
. Individual subjects can have varying iso-slants (iris::data::isoslant
),
so for each subject and display an additional iso-slant correction can be applied when displaying
stimuli.
The calibration and configuration data can be stored globally,
/etc/iris
, or locally per user at ~/.config/iris
. The basic
layout is the following:
[store root]
├── cones/ # cone sensitivies data
│ └── [email protected] # SML data, starting 380nm, 4nm steps
├── default.font -> fonts/OpenSans.ttf # link to default font
├── default.monitor -> monitors/eDP-1 # link to default monitor
├── fonts/ # all fonts
├── links.cfg # output to monitor description
├── monitors/ # all known montors
│ └── sony_gdmf520_77 # example monitor
│ ├── 20150602.settings # description of monitor settings (brightness, …)
│ ├── 20150602T1807.rgb2lms # calibration data from spectra (`iris-calibrate`)
│ ├── 20150608T1549.cac # calibration data like above, in hdf5 format
│ ├── sony_gdmf520_77.monitor # description of the monitor (model, name, …)
│ └── spectra-20150617T1737.h5 # measured monitor spectra (`iris-measure`)
├── subjects/ # registred subjects
│ └── tsubject # subject, "Test Subject" (tsubject)
│ ├── 20150827T1755.isodata # measured isoslant data (`iris-isoslant`)
│ ├── 20150827T1755.isoslant # isoslant calibration form isodata (`iris-fitiso`)
│ └── tsubject.subject # subject description
└── version # store format version, currently "1.0\n"
Most measured data (*.cac
, *.isodata
, *.h5
) are stored in the HDF5
format. The rest of the data is in YAML.
We need to blacklist the cdc-acm
kernel module that otherwise might be
loaded and bind earlier. At least the PR655 needs the usbserial
. This
can be done by creatin a file called /etc/modprobe.d/pr665.conf
with
the following contents (see modprobe.conf(5)
):
#PR655 should use usbserial
blacklist cdc-acm
The following set of commands will use the PR655 connected to /dev/ttyUSB0
to calibrate the screen of 395 mm
width by 295 mm
height.
iris-measure --device=/dev/ttyUSB0 calib.stim
iris-calibrate -W 395 -H 295 spectra-20150814T1522.h5