Added

  • boiler heatingactivated, automatic select parameter telegrams for write
  • boiler wWType parameter, in Console and MQTT
  • support for uploading compressed firmware binaries in web UI
  • setting to manually override the MQTT retain flag
  • New API via HTTP REST API to read and set values. See https://emsesp.github.io/docs/#/API
  • show commands command
  • exporting of system settings using the system info command in Web and Console. Added link into the Web's Settings page.
  • setting to change how booleans are rendered in MQTT (on/off, true/false, 1/0)
  • enable ADC setting, add boiler circulation commands, add thermostat RC300 summermodes
  • Added all device info to web UI for Thermostat and Boiler
  • Added all device values to Home Assistant MQTT Discovery under separate devices and entities
  • Show Rx and Tx quality in Console and Web UI
  • Added button and tooltip to EMS Devices in Web
  • wwtemp and wwtemplow to MQTT, Console and Web
  • summer, winter modes for the CW400 thermostat
  • new command under system called report. http://ems-esp/api?device=system&cmd=report to generate a report log for troubleshooting
  • thermostat error codes
  • Console command publish ha to also force the creation of the Home Assistant MQTT Discovery topics
  • Heat pump values (dew temperature and relative air humidity)
  • Console up key to repeat last command
  • added RC300 floordrying, building, damped temperature

Fixed

  • fix wwontime readback
  • fixed support for RC300 via MQTT commands (#505)
  • Some minor optimizations to memory handling in the MQTT service
  • Prevent MQTT from publishing empty json payloads
  • Accurate detection of warm water and heating (#515)
  • Fix writing to the Junkers FR120 thermostat
  • support for changing summermode
  • added missing heatingtype to thermostat data
  • handle incomming ems+ read requests, ignore F7 telegrams with 3byte-id
  • fix month for setting clock from NTP

Changed

  • renamed wWCircPumpType to wWChargeType
  • Installation and Configuration notes moved to the official EMS-ESP documentation site
  • call commands can be done from the Console root for all devices
  • Updated EMS-ESP official documentation (https://emsesp.github.io/docs/#/)
  • JWT Secret renamed to Super User Password
  • EMS Devices in Web UI shows button and tooltip to remind users they can click on a device
  • MQTT topic name changes (see doc)
  • Mixing renamed to Mixer

Removed

  • Console contexts for thermostat and boiler
  • Removed option to enable/disable the MQTT Heartbeat. It's always on.