tech-sbus-sniffer

RS485 sniffer and parser of the Tech SBUS protocol

Overview

TECH SBUS is a name used by vendor "Tech Sterowniki" for a custom communication protocol over RS-485, most probably developed by them. The protocol is used by their products - room sensors/regulators and central heating actuator controllers.

This project is a very simple Python script that collects data sent over a RS-485 bus and extracts transmitted temperature and humidity measurements.

It is a result of my reverse engineering of the protocol so only the limited functionality is available at the moment. If time permits new features may be added in future because much more data is transmitted. Everyone's encouraged to contribute.

Devices used for testing:

  • L-X WiFi - central controller
  • R-12S - wired room regulator with air temperature sensor, humidity sensor and a connector for floor temperature NTC sensor

The protocol

The data sent over a serial bus consists of ASCII characters.

A single frame starts with a '>' (0x3E) and ends with a line feed (0x0A). Between these two characters there're two base64-encoded strings:

  1. everything without the last 6 characters: the message
  2. the last 6 characters (without "==" padding): CRC-32 of the message

The structure of the message:

Length (bytes) Function
4 Source address (every regulator or controller has it's own 4-byte address)
2 ? (when measurements are sent it's 50 00; in some other messages it's E9 FD)
4 Destination address
2 ? (looks like it's always the same as the two bytes after the source address)
n The data

The data

Temperature and humidity values

One or multiple parameters can be included in one message. In messages sent from the sensor to the controller three bytes mean the type of the parameter and are followed by two bytes with the value. Types of parameters:

  • 04 00 00 - room temperature
  • 04 01 00 - floor temperature?
  • 04 02 00 - humidity

The values are two-byte integers which divided by 10 give temperature in Celsius degrees or humidity percentage.

Example:

04 00 00 f2 00 04 01 00 04 01 04 02 00 4c 02
^^^^^^^^ ^^^^^ ^^^^^^^^ ^^^^^ ^^^^^^^^ ^^^^^
room     24,2  floor    26    humidity 58,8%
temp     deg   temp     deg

Commands

When the target temperature is changed manually on the room sensor, it sends that information to the controller. Similarily, the controller can send updates about the target temperature to the sensor (for example when temperature change is required as per the configured schedule). The controller also updates the room sensor when heating of the room starts or stops. The command type is 3-byte long and the value is 4-byte long and they all start with 06 which may indicate the length (see above - the parameters that are shorter by 2 bytes start with 04).

  • 06 14 00 01 00 00 00 - heating started
  • 06 14 00 00 00 00 00 - heating stopped
  • 06 20 00 followed by 2 bytes indicating for how long the target temperature is set (in minutes) followed by 00 00 or ff ff ff ff (working according to the schedule)
  • 06 21 00 followed by 2 bytes indicating the target temperature followed by 00 00
  • 06 26 00 followed by 2 bytes indicating the time (or ff ff - schedule?) followed by 2 bytes indicating the target temperature (I'm not sure what's the difference between this paremeter and "06 20 00" & "06 21 00" - they seem to contain the same data / maybe some backward compatibility?)

Example

06 14 00 01 00 00 00 06 20 00 3b 00 00 00 06 21 00 e6 00 00 00 06 26 00 3b 00 e6 00
^^^^^^^  ^^^^^^^^^^^ ^^^^^^^^ ^^^^^^^^^^^ ^^^^^^^^ ^^^^^^^^^^^ ^^^^^^^^ ^^^^^^^^^^^
heating  ON          time     59 minutes  target   23 degrees  time     59 minutes
                                          temp                 & temp   23 degrees

ACK

A node that received a message replies to the sender with an ACK message of the following structure:

ac ff ff ac 44 b5 cc 68
^^^^^^^^^^^ ^^^^^^^^^^^
const       CRC-32 of
            the data
            received

Other values

There're many other types of information transmitted but I didn't have time to analyse them / figure out what is what. I noticed for example date and time transmitted regularly by the central controller as follows:

3f a1 2e d0 24 94 6e 38 00 00 00 00
            ^^^^^^^^^^^
            Seconds from the Unix Epoch
            946770980 = Sat Jan  1 23:56:20 UTC 2000

Script usage

Once started, the script opens the serial port given as the first parameter and starts listening for the communication on the RS485 bus. The messages are saved to the log file specified as the second parameter. The default "debug" logging level logs all messages and a lot of details about the processing. The temperature and humidity values and commands are logged with the "info" level.

Currently the only way to reduce the logging verbosity is to change the following piece of code:

level=logging.DEBUG

to for example:

level=logging.INFO

Starting the script

/usr/bin/python3 ./tech_sbus_sniffer.py /dev/ttyUSB0  ./environment.log
                 ^^^^^^^^^^^^^^^^^^^^^^ ^^^^^^^^^^^^  ^^^^^^^^^^^^^^^^
                 script path            serial        log file path
                                        device

Serial devices

I used USB RS485 serial interfaces with the following chips and they both work fine:

  • FT232RL