[![hacs_badge](https://img.shields.io/badge/HACS-Custom-orange.svg?style=for-the-badge)](https://github.com/custom-components/hacs)
[![hacs_badge](https://img.shields.io/badge/HACS-Custom-orange.svg?style=for-the-badge)](
https://github.com/custom-components/hacs)

# custom_components
missing feature test repository
# HASmartThermostat
## Smart Thermostat with PID controller for Home Assistant
Create a virtual thermostat with accurate and reactive temperature control through PID controller.
[Principle of the PID controller.](https://en.wikipedia.org/wiki/PID_controller)
Any heater or air conditioner unit with ON/OFF switch or pilot wire can be controlled using a pulse width modulation
that depends on the temperature error and its variation over time.

## PID controller thermostat
![](climate_chart.png?raw=true)

### Installation:
## Installation:
I recommend using HACS for easier installation.

### Install using HACS:
Go to HACS, select Integrations, click the three dots menu and select
"Custom repositories". Add the path to the Github repository in the first field, select Integration as category and
click Add. Once back in integrations panel, click the Install button on the Smart Thermostat PID card to install.
Set up the smart thermostat and have fun.

### Manual installation:
1. Go to <conf-dir> default /homeassistant/.homeassistant/ (it's where your configuration.yaml is)
2. Create <conf-dir>/custom_components/ directory if it does not already exist
3. Clone this repository content into <conf-dir>/custom_components/
3. Copy the smart_thermostat folder into <conf-dir>/custom_components/
4. Set up the smart_thermostat and have fun

### Usage:
pid controller will be called periodically.
If no pwm interval is definde. It will set the state of "heater" 0-"difference"
Else it will turn off and on the heater proportionally.

#### Autotune:
You can use the autotune feature to set the PID parameters.

Issue! I'couldn't yet save the settings to the configuration.yaml file.
The PID parmaters set by the autotune won't be stored and the process restarts everytime hassio is restarted.
To save the parameters read log, it will be shown like this:
LOGGER.info("Set Kp, Ki, Kd. Smart thermostat now runs on PID Controller." self.kp , self.ki, self.kd)

### Parameters:

#### Still same:

* name (Required): Name of thermostat
* heater (Required): entity_id for heater switch, must be a toggle device. Becomes air conditioning switch when ac_mode is set to True
* target_sensor (Required): entity_id for a temperature sensor, target_sensor.state must be temperature.
* min_temp (Optional): Set minimum set point available (default: 7)
* max_temp (Optional): Set maximum set point available (default: 35)
* target_temp (Optional): Set initial target temperature. Failure to set this variable will result in target temperature being set to null on startup. As of version 0.59, it will retain the target temperature set before restart if available.
* ac_mode (Optional): Set the switch specified in the heater option to be treated as a cooling device instead of a heating device.
* initial_operation_mode (Optional): Set the initial operation mode. Valid values are off or auto. Value has to be double quoted. If this parameter is not set, it is preferable to set a keep_alive value. This is helpful to align any discrepancies between generic_thermostat and heater state.
* away_temp (Optional): Set the temperature used by “away_mode”. If this is not specified, away_mode feature will not get activated.
## Configuration:
The smart thermostat can be added to Home Assistant after installation by adding a climate section to your
configuration.yaml file.

#### Removed:

* min_cycle_duration (Optional):
* cold_tolerance (Optional):
* hot_tolerance (Optional):

#### Edited:

* keep_alive (Required): Set a keep-alive interval. Interval pid controller will be updated.

#### New:
### Configuration example:
#### configuration.yaml
```
climate:
- platform: smart_thermostat
name: Smart Thermostat Example
heater: switch.on_off_heater
target_sensor: sensor.ambient_temperature
min_temp: 7
max_temp: 28
ac_mode: False
target_temp: 19
keep_alive:
seconds: 60
away_temp: 14
kp : 75
ki : 0.001
kd : 70000
pwm : 00:15:00
```

* kp (Optional): Set PID parameter, p controll value.
* ki (Optional): Set PID parameter, i controll value.
* kd (Optional): Set PID parameter, d controll value.
* pwm (Optional): Set period time for pwm signal in minutes. If it's not set pwm is disabled.
* autotune (Optional): Chose a string for autotune settings. If it's not set autotune is disabled.
tuning_rules
## Usage:
The target sensor measures the ambient temperature while the heater switch controls an ON/OFF heating system.
The PID controller computes the amount of time the heater should remain ON over the PWM period to reach the temperature
set point, in example with PWM set to 15 minutes, if output is 100% the heater will be kept on for the next 15 minutes
PWM period. If PID output is 33%, the heater will be switched ON for 5 minutes only.

By default, the PID controller will be called each time the target sensor is updated. When using main powered sensor
with high sampling rate, the _sampling_period_ parameter should be used to slow down the PID controller refresh rate.

By adjusting the Kp, Ki and Kd gains, you can tune the system response to your liking. You can find many tutorials for
guidance on the web. Here are a few useful links:
* [PID Control made easy](https://www.eurotherm.com/temperature-control/pid-control-made-easy/)
* [Practical PID Process Dynamics with Proportional Pressure Controllers](
https://clippard.com/cms/wiki/practical-pid-process-dynamics-proportional-pressure-controllers)
* [PID Tuner](https://pidtuner.com/)
* [PID development blog from Brett Beauregard](http://brettbeauregard.com/blog/category/pid/)
* [PID controller explained](https://controlguru.com/table-of-contents/)

To make it quick and simple:
* Kp gain adjusts the proportional part of the error compensation. Higher values means
stronger reaction to error. Increase the value for faster rise time.
* Ki gain adjusts the integral part. Integral compensates the residual error when temperature settles in a cumulative
way. The longer the temperature remains below the set point, the higher the integral compensation will be. If your
system settles below the set point, increase the Ki value. If it overshoots the set point, decrease the Ki value.
* Kd gain adjusts the derivative part of the compensation. Derivative compensates the inertia of the system. If the
sensor temperature increases quickly between two samples, the PID will decrease the PWM level accordingly to limit the
overshoot.

![](https://upload.wikimedia.org/wikipedia/commons/4/43/PID_en.svg)

PID output value is the weighted sum of the control terms:\
`error = set_point - current_temperature`\
`di = ` temperature change between last two samples\
`dt = ` time elapsed between last two samples\
`P = Kp * error`\
`I = last_I + (Ki * error * dt)`\
`D = -(Kd * di) / dt`\
`output = P + I + D`\
Output is then limited to 0% to 100% range to control the PWM.

### Autotune (not tested, not guaranteed to work):
You can use the autotune feature to find some working PID parameters.
Add the autotune: parameter with the desired tuning rule, and optionally set the noiseband and lookback duration if the
default 2 hours doesn't match your HVAC system bandwidth.\
Restart Home Assistant to start the thermostat in autotune mode, make a step on the set point (positive for heating,
negative for cooling) and wait for the autotune to finish by checking the _autotune_status_ attribute for success.\
The Kp, Ki and Kd gains will be shown in the attributes and shown in the log like this: **"Set Kp, Ki, Kd. Smart
thermostat now runs on PID Controller."** followed by the three computed gains Kp, Ki and Kd respectively.

**Warning**: I'couldn't yet save the settings to the configuration.yaml file. The PID parameters set by the autotune
won't be stored and the process restarts everytime Home Assistant is restarted.\
To save the parameters read attributes or log after autotune has finished, manually copy the values in the
corresponding fields and remove the autotune parameter in the YAML configuration file before restarting Home Assistant.

## Parameters:
* **name** (Required): Name of the thermostat.
* **heater** (Required): entity_id for heater switch, must be a toggle device. Becomes air conditioning switch when
ac_mode is set to True.
* **target_sensor** (Required): entity_id for a temperature sensor, target_sensor.state must be temperature.
* **keep_alive** (Required): sets update interval for the PWM pulse width. If interval is too big, the PWM granularity
will be reduced, leading to lower accuracy of temperature control, can be float in seconds, or time hh:mm:ss.
* **kp** (Recommended): Set PID parameter, proportional (p) control value (default 100).
* **ki** (Recommended): Set PID parameter, integral (i) control value (default 0).
* **kd** (Recommended): Set PID parameter, derivative (d) control value (default 0).
* **pwm** (Optional): Set period of the pulse width modulation. If too long, the response time of the thermostat will
be too slow, leading to lower accuracy of temperature control. Can be float in seconds or time hh:mm:ss (default 15mn).
* **sampling_period** (Optional): interval between two computation of the PID. If set to 0, PID computation is called
each time the temperature sensor sends an update. Can be float in seconds or time hh:mm:ss (default 0)
* **precision** (Optional): the adjustment step of the set point (valid are 0.1, 0.5 and 1.0, default 0.1 for Celsius
and 1.0 for Fahrenheit)
* **min_temp** (Optional): Set minimum set point available (default: 7).
* **max_temp** (Optional): Set maximum set point available (default: 35).
* **target_temp** (Optional): Set initial target temperature. If not set target temperature will be set to null on
startup.
* **ac_mode** (Optional): Set the switch specified in the heater option to be treated as a cooling device instead of a
heating device.
* **away_temp** (Optional): Set the temperature used by “away_mode”. If this is not specified, away_mode feature will
not be available.
* **autotune** (Optional): Chose a string for autotune settings. If it's not set, autotune is disabled. The following
tuning_rules are available:

ruler | Kp_divisor, Ki_divisor, Kd_divisor
------------ | -------------
Expand All @@ -67,36 +141,15 @@ ruler | Kp_divisor, Ki_divisor, Kd_divisor
"no-overshoot" | 100, 40, 60
"brewing" | 2.5, 6, 380

* difference (Optional): Set analog output offset to 0. (default : 100). If it's 500 the output Value can be everything between 0, 500.
* noiseband (Optional): (default : 0.5), set noiseband (float): Determines by how much the input value must overshoot/undershoot the setpoint before the state changes.
* **noiseband** (Optional): set noiseband for autotune (float): Determines by how much the input value
must overshoot/undershoot the set point before the state changes (default : 0.5).
* **lookback** (Optional): duration of the signal analysis for the autotune, need to have 5 cycles (temperature crossing
the set point) included in the analysis period, can be float in seconds, or time hh:mm:ss (default 2 hours).

#### configuration.yaml
```
climate:
- platform: smart_thermostat
name: Study
heater: switch.study_heater
target_sensor: sensor.study_temperature
min_temp: 15
max_temp: 21
ac_mode: False
target_temp: 17
keep_alive:
seconds: 5
initial_operation_mode: "off"
away_temp: 16
kp : 5
ki : 3
kd : 2
pwm : 10
autotune : ziegler-nichols
difference : 100
noiseband : 0.5
```
### Help

The python PID module:
### Credits
This code is a fork from Smart Thermostat PID project:
[https://github.com/aendle/custom_components](https://github.com/aendle/custom_components) \
The python PID module with Autotune is based on pid-autotune:
[https://github.com/hirschmann/pid-autotune](https://github.com/hirschmann/pid-autotune)

PID controller explained. Would recommoned to read some of it:
[https://controlguru.com/table-of-contents/](https://controlguru.com/table-of-contents/)
2 changes: 1 addition & 1 deletion custom_components/smart_thermostat/climate.py
Original file line number Diff line number Diff line change
Expand Up @@ -361,7 +361,7 @@ def device_state_attributes(self):
"""attributes to include in entity"""
if self.autotune != "none":
return {
"control_output": 0,
"control_output": self.control_output,
"pid_p": 0,
"pid_i": 0,
"pid_d": 0,
Expand Down
7 changes: 4 additions & 3 deletions custom_components/smart_thermostat/manifest.json
Original file line number Diff line number Diff line change
@@ -1,9 +1,10 @@
{
"domain": "smart_thermostat",
"name": "Smart thermostat",
"documentation": "https://github.com/ScratMan/custom_components",
"documentation": "https://github.com/ScratMan/HASmartThermostat",
"issue_tracker": "https://github.com/ScratMan/HASmartThermostat/issues",
"requirements": [],
"dependencies": [],
"codeowners": [],
"version":"0.0.2"
"codeowners": ["@ScratMan"],
"version": "2021.11.1"
}
4 changes: 2 additions & 2 deletions hacs.json
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
{
"name": "Smart thermostat (PID)",
"country": "US",
"domains": ["switch", "sensor"],
"domains": ["climate"],
"render_readme": true,
"homeassistant": "0.104.2"
}
97 changes: 0 additions & 97 deletions info.md

This file was deleted.

0 comments on commit 5b7f445

Please sign in to comment.