Fix existing logic error related to Cooling Capacity sizing
Browse files Browse the repository at this point in the history
  • Loading branch information
jmarrec committed Aug 21, 2024
1 parent 5dbc7b1 commit f472e96
Showing 1 changed file with 1 addition and 1 deletion.
2 changes: 1 addition & 1 deletion src/EnergyPlus/WindowAC.cc
Original file line number Diff line number Diff line change
Expand Up @@ -1011,7 +1011,7 @@ namespace WindowAC {
zoneEqSizing.SizingMethod(SizingMethod) = CapSizingMethod;
if (CapSizingMethod == CoolingDesignCapacity || CapSizingMethod == CapacityPerFloorArea ||
CapSizingMethod == FractionOfAutosizedCoolingCapacity) {
if (CapSizingMethod == HeatingDesignCapacity) {
if (CapSizingMethod == CoolingDesignCapacity) {
if (zoneHVACSizing.ScaledCoolingCapacity > 0.0) {
zoneEqSizing.CoolingCapacity = true;
zoneEqSizing.DesCoolingLoad = zoneHVACSizing.ScaledCoolingCapacity;
Expand Down