Notifications
You must be signed in to change notification settings - Fork 13
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
WR - known issues (all issues combined) #309
Comments
There is another issue. If a 'fallout' node locks to White Rabbit, it might look at different 'positions' within a 4 ns window. Once locked, it will always remain locked at its initial position. This issue becomes obvious if one compares two timing receivers (time stamping or digital output) with the same signal. The time difference will remain identical as long as none of the two timing receivers is restarted. But after a restart, the time difference might have a different value. This issue seems to be present for all form factors. |
Issue #266: WR node hangs in endless BOOTP loop, when WR PTP link is not established
Issue #256: connection between White Rabbbit node and switch unreliable after reboot of WRS
Issue #111: WR port not reachable after power cycle of WR switch
Issue #51: WR port of node remains down after power cycle of node AND WR switch
The text was updated successfully, but these errors were encountered: