Skip to content

Releases: nobl/ioBroker.senec

Release v1.3.2

29 May 13:07
Compare
Choose a tag to compare
release prep

Release v1.3.1

13 May 14:12
Compare
Choose a tag to compare
release

Release v1.3.0

11 May 07:46
Compare
Choose a tag to compare
prep for release

Release v1.1.1

30 Apr 12:54
Compare
Choose a tag to compare
Release

Release v1.1.0

14 Feb 16:47
Compare
Choose a tag to compare
general testing and auto-publish overhaul

V1.0.13

14 Feb 16:23
Compare
Choose a tag to compare
v1.0.13

enabling auto-npm-publish

1.0.12

09 Nov 13:37
Compare
Choose a tag to compare

Quite some changes - here is an overview:

* set 'supportCustoms' to false so it won't show up in admin custom config
* added state descriptions: FEATURES.SGREADY, WIZARD.SETUP_WALLBOX_MAX_TOTAL_CURRENT_BY_GRID, WIZARD.SG_READY_CURR_MODE, BMS.ERROR, BMS.RECOVERLOCKED, BMS.SERIAL, BMS.START_SELFTEST, BAT1.RESET, BAT1.SELFTEST_ACT, BAT1.SELFTEST_LIMIT, BAT1.SELFTEST_OFF, BAT1.SELFTEST_OVERALL_STATE, BAT1.SELFTEST_STATE, BAT1.SELFTEST_STEP, BAT1.SELFTEST_TIME, BAT1.SERIAL, BAT1.TRIG_ITALY_SELF, BAT1OBJ1.COMM, GRIDCONFIG.AU_SOFT_RAMP_EN, GRIDCONFIG.AU_VRR_MAX, GRIDCONFIG.AU_VRR_MIN, GRIDCONFIG.AU_VVAR_PERCENTAGE, GRIDCONFIG.AU_VVAR_P_MAX, GRIDCONFIG.AU_VVAR_P_MIN, GRIDCONFIG.AU_VVAR_VOLTAGE, GRIDCONFIG.AU_VWC_VOLTAGE, GRIDCONFIG.AU_VWD_VOLTAGE, GRIDCONFIG.CEI_SEGNALE_ESTERNO, GRIDCONFIG.VDELVFRTDISABLE, GRIDCONFIG.VDEURMSMAX10
* Added PV1.MPP_CUR, .MPP_VOL
* update to current adapter template
* Add MPP_INT to high priority variables (#5)
* Added variable mpp_int to high priority.
* Changed unit for variable mpp_int.
* json delivers a non-value (apparently an error message produced by senec itself). Ignoring that.
* fixed representation for temp values (off by *10)
* enforcing conversion of number values to Number(). Otherwise they are created as String in ioBroker
* DateType objects are stored as date again
* changed WIZARD.SETUP_POWER_RULE unit to '%'
* changed name of STATISTIC.STAT_SUM_E_PU to "STAT_SUM Energy PowerUnit"
* changed name of STATISTIC.STAT_SUM_E_WB to "STAT_SUM Energy Wallbox"
* changed name of STATISTIC.LIVE_WB_ENERGY to "Live Wallbox Energy"
* changed name of STATISTIC.LIVE_PU_ENERGY to "Live PowerUnit Energy"
* changed name of WIZARD.PWRCFG_PEAK_PV_POWER to "Configured Peak PV Power"

1.0.9

15 May 09:33
Compare
Choose a tag to compare
  • IP types are shown as IP again.
  • added datapoints for FACTORY along with more state descriptions for Battery Type, Country and System Type.
  • added datapoints for GRIDCONFIG