With A2B settings for TDM2 and TDM Channel Size 16 bit, the audio comes in on the wrong the channel. Consider the following settings:

  • Settings for A2B from Sigma Studio
    sigma-studio-settings
  • Settings for RAD-A2B
    node-settings

Results in the following:

  • Monitoring the RAD-A2B audio
    monitoring

With TDM Channel Size 32 bit, the audio appears in channel 1. Switching both the SigmaStudio A2B settings and RAD-A2B settings to use 16-bit TDM channel size, the expectation is that the audio be in channel 1. However it appears in channel 2.