Notifications
You must be signed in to change notification settings - Fork 104
/
dump_entities.csv
We can't make this file beautiful and searchable because it's too large.
5102 lines (5102 loc) · 846 KB
/
dump_entities.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
device name,device type,product id,shortname,fullname,type [options...] \| (min/max),uom,writeable,discovery entityid v3.4,discovery entityid,modbus unit identifier,modbus block,modbus scale factor,modbus offset,modbus count
CS*800i, Logatherm WLW*,boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
CS*800i, Logatherm WLW*,boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
CS*800i, Logatherm WLW*,boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
CS*800i, Logatherm WLW*,boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
CS*800i, Logatherm WLW*,boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
CS*800i, Logatherm WLW*,boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
CS*800i, Logatherm WLW*,boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
CS*800i, Logatherm WLW*,boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
CS*800i, Logatherm WLW*,boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
CS*800i, Logatherm WLW*,boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
CS*800i, Logatherm WLW*,boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
CS*800i, Logatherm WLW*,boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
CS*800i, Logatherm WLW*,boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
CS*800i, Logatherm WLW*,boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
CS*800i, Logatherm WLW*,boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
CS*800i, Logatherm WLW*,boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
CS*800i, Logatherm WLW*,boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
CS*800i, Logatherm WLW*,boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
CS*800i, Logatherm WLW*,boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
CS*800i, Logatherm WLW*,boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
CS*800i, Logatherm WLW*,boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
CS*800i, Logatherm WLW*,boiler,8,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1
CS*800i, Logatherm WLW*,boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1
CS*800i, Logatherm WLW*,boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1
CS*800i, Logatherm WLW*,boiler,8,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2
CS*800i, Logatherm WLW*,boiler,8,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2
CS*800i, Logatherm WLW*,boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2
CS*800i, Logatherm WLW*,boiler,8,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2
CS*800i, Logatherm WLW*,boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2
CS*800i, Logatherm WLW*,boiler,8,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2
CS*800i, Logatherm WLW*,boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28
CS*800i, Logatherm WLW*,boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2
CS*800i, Logatherm WLW*,boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1
CS*800i, Logatherm WLW*,boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2
CS*800i, Logatherm WLW*,boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1
CS*800i, Logatherm WLW*,boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1
CS*800i, Logatherm WLW*,boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6
CS*800i, Logatherm WLW*,boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1
CS*800i, Logatherm WLW*,boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1
CS*800i, Logatherm WLW*,boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2
CS*800i, Logatherm WLW*,boiler,8,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2
CS*800i, Logatherm WLW*,boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,82,2
CS*800i, Logatherm WLW*,boiler,8,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,264,2
CS*800i, Logatherm WLW*,boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,84,2
CS*800i, Logatherm WLW*,boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,86,2
CS*800i, Logatherm WLW*,boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,88,2
CS*800i, Logatherm WLW*,boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,90,2
CS*800i, Logatherm WLW*,boiler,8,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,266,2
CS*800i, Logatherm WLW*,boiler,8,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2
CS*800i, Logatherm WLW*,boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,92,2
CS*800i, Logatherm WLW*,boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,94,2
CS*800i, Logatherm WLW*,boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,96,2
CS*800i, Logatherm WLW*,boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,98,2
CS*800i, Logatherm WLW*,boiler,8,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2
CS*800i, Logatherm WLW*,boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,100,2
CS*800i, Logatherm WLW*,boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,102,2
CS*800i, Logatherm WLW*,boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,104,2
CS*800i, Logatherm WLW*,boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,106,2
CS*800i, Logatherm WLW*,boiler,8,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2,5,9,1,6,2
CS*800i, Logatherm WLW*,boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,108,2
CS*800i, Logatherm WLW*,boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,110,2
CS*800i, Logatherm WLW*,boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,112,2
CS*800i, Logatherm WLW*,boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,114,2
CS*800i, Logatherm WLW*,boiler,8,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2
CS*800i, Logatherm WLW*,boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,116,2
CS*800i, Logatherm WLW*,boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,118,2
CS*800i, Logatherm WLW*,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,120,2
CS*800i, Logatherm WLW*,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,122,2
CS*800i, Logatherm WLW*,boiler,8,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2
CS*800i, Logatherm WLW*,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,124,2
CS*800i, Logatherm WLW*,boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,126,2
CS*800i, Logatherm WLW*,boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,128,2
CS*800i, Logatherm WLW*,boiler,8,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2
CS*800i, Logatherm WLW*,boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,130,2
CS*800i, Logatherm WLW*,boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,132,2
CS*800i, Logatherm WLW*,boiler,8,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,134,1
CS*800i, Logatherm WLW*,boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,135,1
CS*800i, Logatherm WLW*,boiler,8,pvmaxcomp,pv compressor max power,uint8 (>=0<=25),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,5,0,1/10,-1,1
CS*800i, Logatherm WLW*,boiler,8,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress,5,0,50,136,1
CS*800i, Logatherm WLW*,boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,137,1
CS*800i, Logatherm WLW*,boiler,8,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,138,1
CS*800i, Logatherm WLW*,boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,139,1
CS*800i, Logatherm WLW*,boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,140,1
CS*800i, Logatherm WLW*,boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,141,1
CS*800i, Logatherm WLW*,boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,142,1
CS*800i, Logatherm WLW*,boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,143,1
CS*800i, Logatherm WLW*,boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,144,1
CS*800i, Logatherm WLW*,boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,145,1
CS*800i, Logatherm WLW*,boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,146,1
CS*800i, Logatherm WLW*,boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,147,1
CS*800i, Logatherm WLW*,boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,148,1
CS*800i, Logatherm WLW*,boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,149,1
CS*800i, Logatherm WLW*,boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,150,1
CS*800i, Logatherm WLW*,boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,151,1
CS*800i, Logatherm WLW*,boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,152,1
CS*800i, Logatherm WLW*,boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,153,1
CS*800i, Logatherm WLW*,boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,154,1
CS*800i, Logatherm WLW*,boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,155,1
CS*800i, Logatherm WLW*,boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,156,1
CS*800i, Logatherm WLW*,boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,157,1
CS*800i, Logatherm WLW*,boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,158,1
CS*800i, Logatherm WLW*,boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,159,1
CS*800i, Logatherm WLW*,boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,160,1
CS*800i, Logatherm WLW*,boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,161,1
CS*800i, Logatherm WLW*,boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,162,8
CS*800i, Logatherm WLW*,boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,170,1
CS*800i, Logatherm WLW*,boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,171,8
CS*800i, Logatherm WLW*,boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,179,1
CS*800i, Logatherm WLW*,boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,180,8
CS*800i, Logatherm WLW*,boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,188,1
CS*800i, Logatherm WLW*,boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,189,8
CS*800i, Logatherm WLW*,boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,197,1
CS*800i, Logatherm WLW*,boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,198,1
CS*800i, Logatherm WLW*,boiler,8,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1
CS*800i, Logatherm WLW*,boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,199,1
CS*800i, Logatherm WLW*,boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,200,1
CS*800i, Logatherm WLW*,boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,201,1
CS*800i, Logatherm WLW*,boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,202,1
CS*800i, Logatherm WLW*,boiler,8,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,203,1
CS*800i, Logatherm WLW*,boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,204,1
CS*800i, Logatherm WLW*,boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,205,1
CS*800i, Logatherm WLW*,boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,206,1
CS*800i, Logatherm WLW*,boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,207,1
CS*800i, Logatherm WLW*,boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,208,1
CS*800i, Logatherm WLW*,boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,209,1
CS*800i, Logatherm WLW*,boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,210,1
CS*800i, Logatherm WLW*,boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,211,1
CS*800i, Logatherm WLW*,boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,212,1
CS*800i, Logatherm WLW*,boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,213,1
CS*800i, Logatherm WLW*,boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,214,1
CS*800i, Logatherm WLW*,boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,215,1
CS*800i, Logatherm WLW*,boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,216,1
CS*800i, Logatherm WLW*,boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,217,1
CS*800i, Logatherm WLW*,boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,218,1
CS*800i, Logatherm WLW*,boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,219,1
CS*800i, Logatherm WLW*,boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,220,1
CS*800i, Logatherm WLW*,boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,221,1
CS*800i, Logatherm WLW*,boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,222,1
CS*800i, Logatherm WLW*,boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,223,1
CS*800i, Logatherm WLW*,boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,224,1
CS*800i, Logatherm WLW*,boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,225,1
CS*800i, Logatherm WLW*,boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,226,1
CS*800i, Logatherm WLW*,boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,227,1
CS*800i, Logatherm WLW*,boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,228,1
CS*800i, Logatherm WLW*,boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,229,1
CS*800i, Logatherm WLW*,boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,230,1
CS*800i, Logatherm WLW*,boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,231,1
CS*800i, Logatherm WLW*,boiler,8,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,268,1
CS*800i, Logatherm WLW*,boiler,8,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,269,1
CS*800i, Logatherm WLW*,boiler,8,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,270,1
CS*800i, Logatherm WLW*,boiler,8,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,271,1
CS*800i, Logatherm WLW*,boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,272,1
CS*800i, Logatherm WLW*,boiler,8,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,273,1
CS*800i, Logatherm WLW*,boiler,8,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1
CS*800i, Logatherm WLW*,boiler,8,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1
CS*800i, Logatherm WLW*,boiler,8,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1
CS*800i, Logatherm WLW*,boiler,8,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1
CS*800i, Logatherm WLW*,boiler,8,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1
CS*800i, Logatherm WLW*,boiler,8,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1
CS*800i, Logatherm WLW*,boiler,8,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1
CS*800i, Logatherm WLW*,boiler,8,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1
CS*800i, Logatherm WLW*,boiler,8,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1
CS*800i, Logatherm WLW*,boiler,8,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1
CS*800i, Logatherm WLW*,boiler,8,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1
CS*800i, Logatherm WLW*,boiler,8,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1
CS*800i, Logatherm WLW*,boiler,8,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1
CS*800i, Logatherm WLW*,boiler,8,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
CS*800i, Logatherm WLW*,boiler,8,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
CS*800i, Logatherm WLW*,boiler,8,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
CS*800i, Logatherm WLW*,boiler,8,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
CS*800i, Logatherm WLW*,boiler,8,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
CS*800i, Logatherm WLW*,boiler,8,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
CS*800i, Logatherm WLW*,boiler,8,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
CS*800i, Logatherm WLW*,boiler,8,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
CS*800i, Logatherm WLW*,boiler,8,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
CS*800i, Logatherm WLW*,boiler,8,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
CS*800i, Logatherm WLW*,boiler,8,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
CS*800i, Logatherm WLW*,boiler,8,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
CS*800i, Logatherm WLW*,boiler,8,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
CS*800i, Logatherm WLW*,boiler,8,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
CS*800i, Logatherm WLW*,boiler,8,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
CS*800i, Logatherm WLW*,boiler,8,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
CS*800i, Logatherm WLW*,boiler,8,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
CS*800i, Logatherm WLW*,boiler,8,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
CS*800i, Logatherm WLW*,boiler,8,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
CS*800i, Logatherm WLW*,boiler,8,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
CS*800i, Logatherm WLW*,boiler,8,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
CS*800i, Logatherm WLW*,boiler,8,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
CS*800i, Logatherm WLW*,boiler,8,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
CS*800i, Logatherm WLW*,boiler,8,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
CS*800i, Logatherm WLW*,boiler,8,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
CS*800i, Logatherm WLW*,boiler,8,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
CS*800i, Logatherm WLW*,boiler,8,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
CS*800i, Logatherm WLW*,boiler,8,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
CS*800i, Logatherm WLW*,boiler,8,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
CS*800i, Logatherm WLW*,boiler,8,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
CS*800i, Logatherm WLW*,boiler,8,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
CS*800i, Logatherm WLW*,boiler,8,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
CS*800i, Logatherm WLW*,boiler,8,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
CS*800i, Logatherm WLW*,boiler,8,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
CS*800i, Logatherm WLW*,boiler,8,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
CS*800i, Logatherm WLW*,boiler,8,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
CS*800i, Logatherm WLW*,boiler,8,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
CS*800i, Logatherm WLW*,boiler,8,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
CS*800i, Logatherm WLW*,boiler,8,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
C1200W,boiler,12,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
C1200W,boiler,12,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
C1200W,boiler,12,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
C1200W,boiler,12,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
C1200W,boiler,12,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
C1200W,boiler,12,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
C1200W,boiler,12,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
C1200W,boiler,12,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
C1200W,boiler,12,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
C1200W,boiler,12,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
C1200W,boiler,12,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
C1200W,boiler,12,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
C1200W,boiler,12,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
C1200W,boiler,12,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1
C1200W,boiler,12,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1
C1200W,boiler,12,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1
C1200W,boiler,12,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1
C1200W,boiler,12,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1
C1200W,boiler,12,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1
C1200W,boiler,12,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1
C1200W,boiler,12,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1
C1200W,boiler,12,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1
C1200W,boiler,12,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1
C1200W,boiler,12,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1
C1200W,boiler,12,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1
C1200W,boiler,12,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1
C1200W,boiler,12,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1
C1200W,boiler,12,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1
C1200W,boiler,12,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1
C1200W,boiler,12,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1
C1200W,boiler,12,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1
C1200W,boiler,12,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1
C1200W,boiler,12,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1
C1200W,boiler,12,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1
C1200W,boiler,12,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1
C1200W,boiler,12,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
C1200W,boiler,12,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
C1200W,boiler,12,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
C1200W,boiler,12,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
C1200W,boiler,12,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
C1200W,boiler,12,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
C1200W,boiler,12,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
C1200W,boiler,12,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
C1200W,boiler,12,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1
C1200W,boiler,12,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1
C1200W,boiler,12,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1
C1200W,boiler,12,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2
C1200W,boiler,12,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2
C1200W,boiler,12,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2
C1200W,boiler,12,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2
C1200W,boiler,12,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2
C1200W,boiler,12,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2
C1200W,boiler,12,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28
C1200W,boiler,12,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2
C1200W,boiler,12,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1
C1200W,boiler,12,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2
C1200W,boiler,12,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1
C1200W,boiler,12,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1
C1200W,boiler,12,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6
C1200W,boiler,12,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1
C1200W,boiler,12,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1
C1200W,boiler,12,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2
C1200W,boiler,12,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2
C1200W,boiler,12,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2
C1200W,boiler,12,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2
C1200W,boiler,12,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2
C1200W,boiler,12,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2
C1200W,boiler,12,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
C1200W,boiler,12,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
C1200W,boiler,12,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
C1200W,boiler,12,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
C1200W,boiler,12,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
C1200W,boiler,12,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
C1200W,boiler,12,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
C1200W,boiler,12,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
C1200W,boiler,12,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
C1200W,boiler,12,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
C1200W,boiler,12,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
C1200W,boiler,12,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
C1200W,boiler,12,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
C1200W,boiler,12,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
C1200W,boiler,12,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
C1200W,boiler,12,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
C1200W,boiler,12,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
C1200W,boiler,12,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
C1200W,boiler,12,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
C1200W,boiler,12,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
C1200W,boiler,12,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
C1200W,boiler,12,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
C1200W,boiler,12,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
C1200W,boiler,12,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
C1200W,boiler,12,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
C1200W,boiler,12,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
C1200W,boiler,12,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
C1200W,boiler,12,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
C1200W,boiler,12,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
C1200W,boiler,12,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
C1200W,boiler,12,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
C1200W,boiler,12,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
C1200W,boiler,12,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
C1200W,boiler,12,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
C1200W,boiler,12,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
C1200W,boiler,12,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
C1200W,boiler,12,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
C1200W,boiler,12,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
C1200W,boiler,12,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
C1200W,boiler,12,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1
C1200W,boiler,12,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2
C1200W,boiler,12,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2
C1200W,boiler,12,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2
BK13/BK15, Smartline, GB1*2,boiler,64,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
BK13/BK15, Smartline, GB1*2,boiler,64,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
BK13/BK15, Smartline, GB1*2,boiler,64,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
BK13/BK15, Smartline, GB1*2,boiler,64,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
BK13/BK15, Smartline, GB1*2,boiler,64,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
BK13/BK15, Smartline, GB1*2,boiler,64,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
BK13/BK15, Smartline, GB1*2,boiler,64,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
BK13/BK15, Smartline, GB1*2,boiler,64,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
BK13/BK15, Smartline, GB1*2,boiler,64,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
BK13/BK15, Smartline, GB1*2,boiler,64,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
BK13/BK15, Smartline, GB1*2,boiler,64,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
BK13/BK15, Smartline, GB1*2,boiler,64,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
BK13/BK15, Smartline, GB1*2,boiler,64,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
BK13/BK15, Smartline, GB1*2,boiler,64,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1
BK13/BK15, Smartline, GB1*2,boiler,64,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1
BK13/BK15, Smartline, GB1*2,boiler,64,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1
BK13/BK15, Smartline, GB1*2,boiler,64,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1
BK13/BK15, Smartline, GB1*2,boiler,64,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1
BK13/BK15, Smartline, GB1*2,boiler,64,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1
BK13/BK15, Smartline, GB1*2,boiler,64,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1
BK13/BK15, Smartline, GB1*2,boiler,64,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1
BK13/BK15, Smartline, GB1*2,boiler,64,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1
BK13/BK15, Smartline, GB1*2,boiler,64,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1
BK13/BK15, Smartline, GB1*2,boiler,64,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1
BK13/BK15, Smartline, GB1*2,boiler,64,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1
BK13/BK15, Smartline, GB1*2,boiler,64,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1
BK13/BK15, Smartline, GB1*2,boiler,64,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1
BK13/BK15, Smartline, GB1*2,boiler,64,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1
BK13/BK15, Smartline, GB1*2,boiler,64,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1
BK13/BK15, Smartline, GB1*2,boiler,64,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1
BK13/BK15, Smartline, GB1*2,boiler,64,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1
BK13/BK15, Smartline, GB1*2,boiler,64,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1
BK13/BK15, Smartline, GB1*2,boiler,64,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1
BK13/BK15, Smartline, GB1*2,boiler,64,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1
BK13/BK15, Smartline, GB1*2,boiler,64,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1
BK13/BK15, Smartline, GB1*2,boiler,64,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
BK13/BK15, Smartline, GB1*2,boiler,64,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
BK13/BK15, Smartline, GB1*2,boiler,64,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
BK13/BK15, Smartline, GB1*2,boiler,64,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
BK13/BK15, Smartline, GB1*2,boiler,64,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
BK13/BK15, Smartline, GB1*2,boiler,64,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
BK13/BK15, Smartline, GB1*2,boiler,64,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
BK13/BK15, Smartline, GB1*2,boiler,64,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
BK13/BK15, Smartline, GB1*2,boiler,64,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1
BK13/BK15, Smartline, GB1*2,boiler,64,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1
BK13/BK15, Smartline, GB1*2,boiler,64,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1
BK13/BK15, Smartline, GB1*2,boiler,64,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2
BK13/BK15, Smartline, GB1*2,boiler,64,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2
BK13/BK15, Smartline, GB1*2,boiler,64,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2
BK13/BK15, Smartline, GB1*2,boiler,64,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2
BK13/BK15, Smartline, GB1*2,boiler,64,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2
BK13/BK15, Smartline, GB1*2,boiler,64,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2
BK13/BK15, Smartline, GB1*2,boiler,64,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28
BK13/BK15, Smartline, GB1*2,boiler,64,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2
BK13/BK15, Smartline, GB1*2,boiler,64,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1
BK13/BK15, Smartline, GB1*2,boiler,64,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2
BK13/BK15, Smartline, GB1*2,boiler,64,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1
BK13/BK15, Smartline, GB1*2,boiler,64,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1
BK13/BK15, Smartline, GB1*2,boiler,64,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6
BK13/BK15, Smartline, GB1*2,boiler,64,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1
BK13/BK15, Smartline, GB1*2,boiler,64,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1
BK13/BK15, Smartline, GB1*2,boiler,64,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2
BK13/BK15, Smartline, GB1*2,boiler,64,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2
BK13/BK15, Smartline, GB1*2,boiler,64,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2
BK13/BK15, Smartline, GB1*2,boiler,64,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2
BK13/BK15, Smartline, GB1*2,boiler,64,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2
BK13/BK15, Smartline, GB1*2,boiler,64,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2
BK13/BK15, Smartline, GB1*2,boiler,64,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
BK13/BK15, Smartline, GB1*2,boiler,64,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
BK13/BK15, Smartline, GB1*2,boiler,64,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
BK13/BK15, Smartline, GB1*2,boiler,64,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
BK13/BK15, Smartline, GB1*2,boiler,64,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
BK13/BK15, Smartline, GB1*2,boiler,64,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
BK13/BK15, Smartline, GB1*2,boiler,64,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
BK13/BK15, Smartline, GB1*2,boiler,64,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
BK13/BK15, Smartline, GB1*2,boiler,64,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
BK13/BK15, Smartline, GB1*2,boiler,64,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
BK13/BK15, Smartline, GB1*2,boiler,64,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
BK13/BK15, Smartline, GB1*2,boiler,64,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
BK13/BK15, Smartline, GB1*2,boiler,64,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
BK13/BK15, Smartline, GB1*2,boiler,64,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
BK13/BK15, Smartline, GB1*2,boiler,64,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
BK13/BK15, Smartline, GB1*2,boiler,64,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
BK13/BK15, Smartline, GB1*2,boiler,64,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
BK13/BK15, Smartline, GB1*2,boiler,64,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
BK13/BK15, Smartline, GB1*2,boiler,64,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
BK13/BK15, Smartline, GB1*2,boiler,64,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
BK13/BK15, Smartline, GB1*2,boiler,64,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
BK13/BK15, Smartline, GB1*2,boiler,64,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
BK13/BK15, Smartline, GB1*2,boiler,64,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
BK13/BK15, Smartline, GB1*2,boiler,64,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
BK13/BK15, Smartline, GB1*2,boiler,64,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
BK13/BK15, Smartline, GB1*2,boiler,64,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
BK13/BK15, Smartline, GB1*2,boiler,64,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
BK13/BK15, Smartline, GB1*2,boiler,64,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
BK13/BK15, Smartline, GB1*2,boiler,64,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
BK13/BK15, Smartline, GB1*2,boiler,64,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
BK13/BK15, Smartline, GB1*2,boiler,64,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
BK13/BK15, Smartline, GB1*2,boiler,64,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
BK13/BK15, Smartline, GB1*2,boiler,64,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
BK13/BK15, Smartline, GB1*2,boiler,64,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
BK13/BK15, Smartline, GB1*2,boiler,64,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
BK13/BK15, Smartline, GB1*2,boiler,64,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
BK13/BK15, Smartline, GB1*2,boiler,64,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
BK13/BK15, Smartline, GB1*2,boiler,64,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
BK13/BK15, Smartline, GB1*2,boiler,64,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
BK13/BK15, Smartline, GB1*2,boiler,64,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1
BK13/BK15, Smartline, GB1*2,boiler,64,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2
BK13/BK15, Smartline, GB1*2,boiler,64,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2
BK13/BK15, Smartline, GB1*2,boiler,64,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2
Logano GB1*5, Logamatic MC10,boiler,72,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
Logano GB1*5, Logamatic MC10,boiler,72,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
Logano GB1*5, Logamatic MC10,boiler,72,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
Logano GB1*5, Logamatic MC10,boiler,72,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
Logano GB1*5, Logamatic MC10,boiler,72,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
Logano GB1*5, Logamatic MC10,boiler,72,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
Logano GB1*5, Logamatic MC10,boiler,72,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
Logano GB1*5, Logamatic MC10,boiler,72,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
Logano GB1*5, Logamatic MC10,boiler,72,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
Logano GB1*5, Logamatic MC10,boiler,72,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
Logano GB1*5, Logamatic MC10,boiler,72,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
Logano GB1*5, Logamatic MC10,boiler,72,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
Logano GB1*5, Logamatic MC10,boiler,72,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
Logano GB1*5, Logamatic MC10,boiler,72,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1
Logano GB1*5, Logamatic MC10,boiler,72,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1
Logano GB1*5, Logamatic MC10,boiler,72,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1
Logano GB1*5, Logamatic MC10,boiler,72,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1
Logano GB1*5, Logamatic MC10,boiler,72,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1
Logano GB1*5, Logamatic MC10,boiler,72,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1
Logano GB1*5, Logamatic MC10,boiler,72,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1
Logano GB1*5, Logamatic MC10,boiler,72,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1
Logano GB1*5, Logamatic MC10,boiler,72,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1
Logano GB1*5, Logamatic MC10,boiler,72,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1
Logano GB1*5, Logamatic MC10,boiler,72,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1
Logano GB1*5, Logamatic MC10,boiler,72,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1
Logano GB1*5, Logamatic MC10,boiler,72,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1
Logano GB1*5, Logamatic MC10,boiler,72,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1
Logano GB1*5, Logamatic MC10,boiler,72,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1
Logano GB1*5, Logamatic MC10,boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1
Logano GB1*5, Logamatic MC10,boiler,72,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1
Logano GB1*5, Logamatic MC10,boiler,72,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1
Logano GB1*5, Logamatic MC10,boiler,72,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1
Logano GB1*5, Logamatic MC10,boiler,72,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1
Logano GB1*5, Logamatic MC10,boiler,72,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1
Logano GB1*5, Logamatic MC10,boiler,72,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1
Logano GB1*5, Logamatic MC10,boiler,72,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
Logano GB1*5, Logamatic MC10,boiler,72,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
Logano GB1*5, Logamatic MC10,boiler,72,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
Logano GB1*5, Logamatic MC10,boiler,72,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
Logano GB1*5, Logamatic MC10,boiler,72,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
Logano GB1*5, Logamatic MC10,boiler,72,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
Logano GB1*5, Logamatic MC10,boiler,72,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
Logano GB1*5, Logamatic MC10,boiler,72,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
Logano GB1*5, Logamatic MC10,boiler,72,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1
Logano GB1*5, Logamatic MC10,boiler,72,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1
Logano GB1*5, Logamatic MC10,boiler,72,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1
Logano GB1*5, Logamatic MC10,boiler,72,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2
Logano GB1*5, Logamatic MC10,boiler,72,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2
Logano GB1*5, Logamatic MC10,boiler,72,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2
Logano GB1*5, Logamatic MC10,boiler,72,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2
Logano GB1*5, Logamatic MC10,boiler,72,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2
Logano GB1*5, Logamatic MC10,boiler,72,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2
Logano GB1*5, Logamatic MC10,boiler,72,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28
Logano GB1*5, Logamatic MC10,boiler,72,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2
Logano GB1*5, Logamatic MC10,boiler,72,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1
Logano GB1*5, Logamatic MC10,boiler,72,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2
Logano GB1*5, Logamatic MC10,boiler,72,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1
Logano GB1*5, Logamatic MC10,boiler,72,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1
Logano GB1*5, Logamatic MC10,boiler,72,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6
Logano GB1*5, Logamatic MC10,boiler,72,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1
Logano GB1*5, Logamatic MC10,boiler,72,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1
Logano GB1*5, Logamatic MC10,boiler,72,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2
Logano GB1*5, Logamatic MC10,boiler,72,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2
Logano GB1*5, Logamatic MC10,boiler,72,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2
Logano GB1*5, Logamatic MC10,boiler,72,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2
Logano GB1*5, Logamatic MC10,boiler,72,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2
Logano GB1*5, Logamatic MC10,boiler,72,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2
Logano GB1*5, Logamatic MC10,boiler,72,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
Logano GB1*5, Logamatic MC10,boiler,72,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
Logano GB1*5, Logamatic MC10,boiler,72,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
Logano GB1*5, Logamatic MC10,boiler,72,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
Logano GB1*5, Logamatic MC10,boiler,72,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
Logano GB1*5, Logamatic MC10,boiler,72,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
Logano GB1*5, Logamatic MC10,boiler,72,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
Logano GB1*5, Logamatic MC10,boiler,72,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
Logano GB1*5, Logamatic MC10,boiler,72,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
Logano GB1*5, Logamatic MC10,boiler,72,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
Logano GB1*5, Logamatic MC10,boiler,72,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
Logano GB1*5, Logamatic MC10,boiler,72,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
Logano GB1*5, Logamatic MC10,boiler,72,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
Logano GB1*5, Logamatic MC10,boiler,72,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
Logano GB1*5, Logamatic MC10,boiler,72,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
Logano GB1*5, Logamatic MC10,boiler,72,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
Logano GB1*5, Logamatic MC10,boiler,72,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
Logano GB1*5, Logamatic MC10,boiler,72,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
Logano GB1*5, Logamatic MC10,boiler,72,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
Logano GB1*5, Logamatic MC10,boiler,72,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
Logano GB1*5, Logamatic MC10,boiler,72,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
Logano GB1*5, Logamatic MC10,boiler,72,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
Logano GB1*5, Logamatic MC10,boiler,72,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
Logano GB1*5, Logamatic MC10,boiler,72,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
Logano GB1*5, Logamatic MC10,boiler,72,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
Logano GB1*5, Logamatic MC10,boiler,72,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
Logano GB1*5, Logamatic MC10,boiler,72,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
Logano GB1*5, Logamatic MC10,boiler,72,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
Logano GB1*5, Logamatic MC10,boiler,72,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
Logano GB1*5, Logamatic MC10,boiler,72,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
Logano GB1*5, Logamatic MC10,boiler,72,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
Logano GB1*5, Logamatic MC10,boiler,72,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
Logano GB1*5, Logamatic MC10,boiler,72,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
Logano GB1*5, Logamatic MC10,boiler,72,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
Logano GB1*5, Logamatic MC10,boiler,72,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
Logano GB1*5, Logamatic MC10,boiler,72,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
Logano GB1*5, Logamatic MC10,boiler,72,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
Logano GB1*5, Logamatic MC10,boiler,72,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
Logano GB1*5, Logamatic MC10,boiler,72,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
Logano GB1*5, Logamatic MC10,boiler,72,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1
Logano GB1*5, Logamatic MC10,boiler,72,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2
Logano GB1*5, Logamatic MC10,boiler,72,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2
Logano GB1*5, Logamatic MC10,boiler,72,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2
Cascade CM10,boiler,81,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
Cascade CM10,boiler,81,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
Cascade CM10,boiler,81,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
Cascade CM10,boiler,81,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
Cascade CM10,boiler,81,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
Cascade CM10,boiler,81,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
Cascade CM10,boiler,81,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
Cascade CM10,boiler,81,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
Cascade CM10,boiler,81,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
Cascade CM10,boiler,81,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
Cascade CM10,boiler,81,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
Cascade CM10,boiler,81,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
Cascade CM10,boiler,81,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
Cascade CM10,boiler,81,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1
Cascade CM10,boiler,81,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1
Cascade CM10,boiler,81,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1
Cascade CM10,boiler,81,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1
Cascade CM10,boiler,81,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1
Cascade CM10,boiler,81,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1
Cascade CM10,boiler,81,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1
Cascade CM10,boiler,81,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1
Cascade CM10,boiler,81,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1
Cascade CM10,boiler,81,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1
Cascade CM10,boiler,81,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1
Cascade CM10,boiler,81,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1
Cascade CM10,boiler,81,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1
Cascade CM10,boiler,81,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1
Cascade CM10,boiler,81,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1
Cascade CM10,boiler,81,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1
Cascade CM10,boiler,81,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1
Cascade CM10,boiler,81,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1
Cascade CM10,boiler,81,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1
Cascade CM10,boiler,81,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1
Cascade CM10,boiler,81,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1
Cascade CM10,boiler,81,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1
Cascade CM10,boiler,81,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
Cascade CM10,boiler,81,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
Cascade CM10,boiler,81,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
Cascade CM10,boiler,81,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
Cascade CM10,boiler,81,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
Cascade CM10,boiler,81,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
Cascade CM10,boiler,81,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
Cascade CM10,boiler,81,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
Cascade CM10,boiler,81,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1
Cascade CM10,boiler,81,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1
Cascade CM10,boiler,81,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1
Cascade CM10,boiler,81,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2
Cascade CM10,boiler,81,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2
Cascade CM10,boiler,81,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2
Cascade CM10,boiler,81,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2
Cascade CM10,boiler,81,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2
Cascade CM10,boiler,81,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2
Cascade CM10,boiler,81,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28
Cascade CM10,boiler,81,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2
Cascade CM10,boiler,81,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1
Cascade CM10,boiler,81,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2
Cascade CM10,boiler,81,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1
Cascade CM10,boiler,81,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1
Cascade CM10,boiler,81,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6
Cascade CM10,boiler,81,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1
Cascade CM10,boiler,81,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1
Cascade CM10,boiler,81,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2
Cascade CM10,boiler,81,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2
Cascade CM10,boiler,81,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2
Cascade CM10,boiler,81,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2
Cascade CM10,boiler,81,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2
Cascade CM10,boiler,81,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2
Cascade CM10,boiler,81,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
Cascade CM10,boiler,81,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
Cascade CM10,boiler,81,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
Cascade CM10,boiler,81,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
Cascade CM10,boiler,81,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
Cascade CM10,boiler,81,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
Cascade CM10,boiler,81,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
Cascade CM10,boiler,81,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
Cascade CM10,boiler,81,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
Cascade CM10,boiler,81,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
Cascade CM10,boiler,81,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
Cascade CM10,boiler,81,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
Cascade CM10,boiler,81,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
Cascade CM10,boiler,81,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
Cascade CM10,boiler,81,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
Cascade CM10,boiler,81,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
Cascade CM10,boiler,81,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
Cascade CM10,boiler,81,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
Cascade CM10,boiler,81,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
Cascade CM10,boiler,81,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
Cascade CM10,boiler,81,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
Cascade CM10,boiler,81,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
Cascade CM10,boiler,81,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
Cascade CM10,boiler,81,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
Cascade CM10,boiler,81,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
Cascade CM10,boiler,81,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
Cascade CM10,boiler,81,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
Cascade CM10,boiler,81,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
Cascade CM10,boiler,81,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
Cascade CM10,boiler,81,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
Cascade CM10,boiler,81,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
Cascade CM10,boiler,81,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
Cascade CM10,boiler,81,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
Cascade CM10,boiler,81,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
Cascade CM10,boiler,81,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
Cascade CM10,boiler,81,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
Cascade CM10,boiler,81,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
Cascade CM10,boiler,81,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
Cascade CM10,boiler,81,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
Cascade CM10,boiler,81,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1
Cascade CM10,boiler,81,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2
Cascade CM10,boiler,81,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2
Cascade CM10,boiler,81,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2
Logamax Plus GB022,boiler,84,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
Logamax Plus GB022,boiler,84,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
Logamax Plus GB022,boiler,84,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
Logamax Plus GB022,boiler,84,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
Logamax Plus GB022,boiler,84,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
Logamax Plus GB022,boiler,84,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
Logamax Plus GB022,boiler,84,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
Logamax Plus GB022,boiler,84,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
Logamax Plus GB022,boiler,84,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
Logamax Plus GB022,boiler,84,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
Logamax Plus GB022,boiler,84,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
Logamax Plus GB022,boiler,84,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
Logamax Plus GB022,boiler,84,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
Logamax Plus GB022,boiler,84,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1
Logamax Plus GB022,boiler,84,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1
Logamax Plus GB022,boiler,84,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1
Logamax Plus GB022,boiler,84,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1
Logamax Plus GB022,boiler,84,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1
Logamax Plus GB022,boiler,84,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1
Logamax Plus GB022,boiler,84,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1
Logamax Plus GB022,boiler,84,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1
Logamax Plus GB022,boiler,84,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1
Logamax Plus GB022,boiler,84,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1
Logamax Plus GB022,boiler,84,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1
Logamax Plus GB022,boiler,84,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1
Logamax Plus GB022,boiler,84,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1
Logamax Plus GB022,boiler,84,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1
Logamax Plus GB022,boiler,84,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1
Logamax Plus GB022,boiler,84,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1
Logamax Plus GB022,boiler,84,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1
Logamax Plus GB022,boiler,84,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1
Logamax Plus GB022,boiler,84,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1
Logamax Plus GB022,boiler,84,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1
Logamax Plus GB022,boiler,84,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1
Logamax Plus GB022,boiler,84,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1
Logamax Plus GB022,boiler,84,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
Logamax Plus GB022,boiler,84,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
Logamax Plus GB022,boiler,84,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
Logamax Plus GB022,boiler,84,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
Logamax Plus GB022,boiler,84,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
Logamax Plus GB022,boiler,84,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
Logamax Plus GB022,boiler,84,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
Logamax Plus GB022,boiler,84,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
Logamax Plus GB022,boiler,84,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1
Logamax Plus GB022,boiler,84,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1
Logamax Plus GB022,boiler,84,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1
Logamax Plus GB022,boiler,84,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2
Logamax Plus GB022,boiler,84,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2
Logamax Plus GB022,boiler,84,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2
Logamax Plus GB022,boiler,84,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2
Logamax Plus GB022,boiler,84,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2
Logamax Plus GB022,boiler,84,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2
Logamax Plus GB022,boiler,84,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28
Logamax Plus GB022,boiler,84,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2
Logamax Plus GB022,boiler,84,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1
Logamax Plus GB022,boiler,84,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2
Logamax Plus GB022,boiler,84,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1
Logamax Plus GB022,boiler,84,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1
Logamax Plus GB022,boiler,84,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6
Logamax Plus GB022,boiler,84,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1
Logamax Plus GB022,boiler,84,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1
Logamax Plus GB022,boiler,84,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2
Logamax Plus GB022,boiler,84,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2
Logamax Plus GB022,boiler,84,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2
Logamax Plus GB022,boiler,84,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2
Logamax Plus GB022,boiler,84,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2
Logamax Plus GB022,boiler,84,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2
Logamax Plus GB022,boiler,84,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
Logamax Plus GB022,boiler,84,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
Logamax Plus GB022,boiler,84,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
Logamax Plus GB022,boiler,84,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
Logamax Plus GB022,boiler,84,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
Logamax Plus GB022,boiler,84,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
Logamax Plus GB022,boiler,84,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
Logamax Plus GB022,boiler,84,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
Logamax Plus GB022,boiler,84,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
Logamax Plus GB022,boiler,84,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
Logamax Plus GB022,boiler,84,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
Logamax Plus GB022,boiler,84,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
Logamax Plus GB022,boiler,84,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
Logamax Plus GB022,boiler,84,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
Logamax Plus GB022,boiler,84,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
Logamax Plus GB022,boiler,84,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
Logamax Plus GB022,boiler,84,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
Logamax Plus GB022,boiler,84,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
Logamax Plus GB022,boiler,84,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
Logamax Plus GB022,boiler,84,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
Logamax Plus GB022,boiler,84,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
Logamax Plus GB022,boiler,84,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
Logamax Plus GB022,boiler,84,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
Logamax Plus GB022,boiler,84,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
Logamax Plus GB022,boiler,84,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
Logamax Plus GB022,boiler,84,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
Logamax Plus GB022,boiler,84,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
Logamax Plus GB022,boiler,84,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
Logamax Plus GB022,boiler,84,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
Logamax Plus GB022,boiler,84,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
Logamax Plus GB022,boiler,84,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
Logamax Plus GB022,boiler,84,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
Logamax Plus GB022,boiler,84,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
Logamax Plus GB022,boiler,84,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
Logamax Plus GB022,boiler,84,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
Logamax Plus GB022,boiler,84,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
Logamax Plus GB022,boiler,84,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
Logamax Plus GB022,boiler,84,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
Logamax Plus GB022,boiler,84,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
Logamax Plus GB022,boiler,84,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1
Logamax Plus GB022,boiler,84,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2
Logamax Plus GB022,boiler,84,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2
Logamax Plus GB022,boiler,84,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2
Topline, GB162,boiler,115,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
Topline, GB162,boiler,115,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
Topline, GB162,boiler,115,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
Topline, GB162,boiler,115,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
Topline, GB162,boiler,115,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
Topline, GB162,boiler,115,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
Topline, GB162,boiler,115,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
Topline, GB162,boiler,115,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
Topline, GB162,boiler,115,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
Topline, GB162,boiler,115,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
Topline, GB162,boiler,115,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
Topline, GB162,boiler,115,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
Topline, GB162,boiler,115,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
Topline, GB162,boiler,115,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1
Topline, GB162,boiler,115,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1
Topline, GB162,boiler,115,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1
Topline, GB162,boiler,115,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1
Topline, GB162,boiler,115,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1
Topline, GB162,boiler,115,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1
Topline, GB162,boiler,115,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1
Topline, GB162,boiler,115,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1
Topline, GB162,boiler,115,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1
Topline, GB162,boiler,115,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1
Topline, GB162,boiler,115,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1
Topline, GB162,boiler,115,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1
Topline, GB162,boiler,115,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1
Topline, GB162,boiler,115,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1
Topline, GB162,boiler,115,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1
Topline, GB162,boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1
Topline, GB162,boiler,115,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1
Topline, GB162,boiler,115,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1
Topline, GB162,boiler,115,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1
Topline, GB162,boiler,115,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1
Topline, GB162,boiler,115,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1
Topline, GB162,boiler,115,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1
Topline, GB162,boiler,115,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
Topline, GB162,boiler,115,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
Topline, GB162,boiler,115,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
Topline, GB162,boiler,115,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
Topline, GB162,boiler,115,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
Topline, GB162,boiler,115,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
Topline, GB162,boiler,115,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
Topline, GB162,boiler,115,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
Topline, GB162,boiler,115,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1
Topline, GB162,boiler,115,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1
Topline, GB162,boiler,115,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1
Topline, GB162,boiler,115,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2
Topline, GB162,boiler,115,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2
Topline, GB162,boiler,115,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2
Topline, GB162,boiler,115,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2
Topline, GB162,boiler,115,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2
Topline, GB162,boiler,115,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2
Topline, GB162,boiler,115,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28
Topline, GB162,boiler,115,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2
Topline, GB162,boiler,115,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1
Topline, GB162,boiler,115,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2
Topline, GB162,boiler,115,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1
Topline, GB162,boiler,115,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1
Topline, GB162,boiler,115,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6
Topline, GB162,boiler,115,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1
Topline, GB162,boiler,115,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1
Topline, GB162,boiler,115,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2
Topline, GB162,boiler,115,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2
Topline, GB162,boiler,115,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2
Topline, GB162,boiler,115,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2
Topline, GB162,boiler,115,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2
Topline, GB162,boiler,115,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2
Topline, GB162,boiler,115,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
Topline, GB162,boiler,115,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
Topline, GB162,boiler,115,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
Topline, GB162,boiler,115,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
Topline, GB162,boiler,115,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
Topline, GB162,boiler,115,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
Topline, GB162,boiler,115,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
Topline, GB162,boiler,115,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
Topline, GB162,boiler,115,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
Topline, GB162,boiler,115,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
Topline, GB162,boiler,115,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
Topline, GB162,boiler,115,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
Topline, GB162,boiler,115,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
Topline, GB162,boiler,115,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
Topline, GB162,boiler,115,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
Topline, GB162,boiler,115,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
Topline, GB162,boiler,115,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
Topline, GB162,boiler,115,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
Topline, GB162,boiler,115,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
Topline, GB162,boiler,115,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
Topline, GB162,boiler,115,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
Topline, GB162,boiler,115,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
Topline, GB162,boiler,115,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
Topline, GB162,boiler,115,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
Topline, GB162,boiler,115,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
Topline, GB162,boiler,115,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
Topline, GB162,boiler,115,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
Topline, GB162,boiler,115,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
Topline, GB162,boiler,115,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
Topline, GB162,boiler,115,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
Topline, GB162,boiler,115,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
Topline, GB162,boiler,115,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
Topline, GB162,boiler,115,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
Topline, GB162,boiler,115,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
Topline, GB162,boiler,115,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
Topline, GB162,boiler,115,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
Topline, GB162,boiler,115,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
Topline, GB162,boiler,115,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
Topline, GB162,boiler,115,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
Topline, GB162,boiler,115,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1
Topline, GB162,boiler,115,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2
Topline, GB162,boiler,115,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2
Topline, GB162,boiler,115,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2
Cascade MCM10,boiler,121,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
Cascade MCM10,boiler,121,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
Cascade MCM10,boiler,121,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
Cascade MCM10,boiler,121,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
Cascade MCM10,boiler,121,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
Cascade MCM10,boiler,121,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
Cascade MCM10,boiler,121,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
Cascade MCM10,boiler,121,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
Cascade MCM10,boiler,121,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
Cascade MCM10,boiler,121,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
Cascade MCM10,boiler,121,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
Cascade MCM10,boiler,121,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
Cascade MCM10,boiler,121,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
Cascade MCM10,boiler,121,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1
Cascade MCM10,boiler,121,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1
Cascade MCM10,boiler,121,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1
Cascade MCM10,boiler,121,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1
Cascade MCM10,boiler,121,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1
Cascade MCM10,boiler,121,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1
Cascade MCM10,boiler,121,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1
Cascade MCM10,boiler,121,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1
Cascade MCM10,boiler,121,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1
Cascade MCM10,boiler,121,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1
Cascade MCM10,boiler,121,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1