Notifications
You must be signed in to change notification settings - Fork 3
/
Uart8Receiver.v
308 lines (292 loc) · 12 KB
/
Uart8Receiver.v
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
`include "UartStates.vh"
/*
* 8-bit UART Receiver
*
* Able to receive 8 bits of serial data, one start bit, one stop bit
*
* When receive is detected and in progress over {in}, {busy} is driven high
*
* When receive is complete, {done} is driven high for one serial bit cycle
* (aka baud interval: equal to 16 {clk} ticks)
*
* Output data should be taken away within one baud interval or it will be lost
*
* System clock must be divided down to oversampling rate times baud rate
* to provide the {clk} input
*
* (*Note this module's logic is hard-coded based on 16x oversampling rate)
*/
module Uart8Receiver (
input wire clk, // rx data sampling rate
input wire en,
input wire in, // rx line
output reg busy, // transaction is in progress
output reg done, // end of transaction
output reg err, // error while receiving data
output reg [7:0] out // the received data assembled in parallel form
);
reg [2:0] state = `RESET;
reg [1:0] in_reg = 2'b0; // shift reg for input signal conditioning
reg [4:0] in_hold_reg = 5'b0; // shift reg for signal hold time checks
reg [3:0] sample_count = 4'b0; // count ticks for 16x oversample
reg [4:0] out_hold_count = 5'b0; // count ticks before clearing output data
reg [2:0] bit_index = 3'b0; // index for 8-bit data
reg [7:0] received_data = 8'b0; // shift reg for the deserialized data
wire in_sample;
wire [3:0] in_prior_hold_reg;
wire [3:0] in_current_hold_reg;
/*
* Double-register the incoming data:
*
* This prevents metastability problems crossing into rx clock domain
*
* After registering, only the in_sample wire is to be accessed - the
* earlier, unconditioned signal {in} must be ignored
*/
always @(posedge clk) begin
in_reg <= { in_reg[0], in };
end
assign in_sample = in_reg[1];
/*
* Track the incoming data for 4 rx {clk} ticks + 1, to be able to enforce a
* minimum hold time of 4 {clk} ticks for any rx signal
*/
always @(posedge clk) begin
in_hold_reg <= { in_hold_reg[3:1], in_sample, in_reg[0] };
end
assign in_prior_hold_reg = in_hold_reg[4:1];
assign in_current_hold_reg = in_hold_reg[3:0];
/*
* End the validity of output data after precise time of one serial bit cycle:
*
* Output signals from this module might as well be consistent with input
* rate, which is the baud rate
*
* This hold is for the case when detection of a next transmit cut the
* prior stop and ready transitions short; i.e. IDLE state has been entered
* direct from STOP_BIT state or READY state
*/
always @(posedge clk) begin
if (|out_hold_count) begin
out_hold_count <= out_hold_count + 5'b1;
if (out_hold_count == 5'b10000) begin // reached 16 -
// timed output interval ends
out_hold_count <= 5'b0;
done <= 1'b0;
out <= 8'b0;
end
end
end
/*
* Disable at any time in the flow
*/
always @(posedge clk) begin
if (!en) begin
state <= `RESET;
end
end
/*
* State machine
*/
always @(posedge clk) begin
case (state)
`RESET: begin
// state variables
sample_count <= 4'b0;
out_hold_count <= 5'b0;
received_data <= 8'b0;
// outputs
busy <= 1'b0;
done <= 1'b0;
if (en && err && !in_sample) begin // in error condition already -
// leave the output uninterrupted
err <= 1'b1;
end else begin
err <= 1'b0;
end
out <= 8'b0; // output parallel data only during {done}
// next state
if (en) begin
state <= `IDLE;
end
end
`IDLE: begin
/*
* Accept low-going input as the trigger to start:
*
* Count from the first low sample, and sample again at the
* mid-point of a full baud interval to accept the low signal
*
* Then start the count for the proceeding full baud intervals
*/
if (!in_sample) begin
if (sample_count == 4'b0) begin
if (&in_prior_hold_reg || done && !err) begin
// meets the preceding min high hold time -
// note that {done} && !{err} encodes the fact that
// the min hold time was met earlier in STOP_BIT state
// or READY state
sample_count <= 4'b1;
err <= 1'b0;
end else begin
// this was a false start -
// remain in IDLE state with sample_count zero
err <= 1'b1;
end
end else begin
sample_count <= sample_count + 4'b1;
if (sample_count == 4'b1100) begin // reached 12
// start signal meets an additional hold time
// of >= 4 rx ticks after its own mid-point -
// start new full interval count but from the mid-point
sample_count <= 4'b0100;
busy <= 1'b1;
err <= 1'b0;
state <= `START_BIT;
end
end
end else if (|sample_count) begin
// bit did not remain low while waiting till 8 then 12 -
// remain in IDLE state
sample_count <= 4'b0;
received_data <= 8'b0;
err <= 1'b1;
end
end
`START_BIT: begin
/*
* Wait one full baud interval to the mid-point of first bit
*/
sample_count <= sample_count + 4'b1;
if (&sample_count) begin // reached 15
// sample_count wraps around to zero
bit_index <= 3'b1;
received_data <= { in_sample, 7'b0 };
out <= 8'b0;
state <= `DATA_BITS;
end
end
`DATA_BITS: begin
/*
* Take 8 baud intervals to receive serial data
*/
sample_count <= sample_count + 4'b1;
if (&sample_count) begin // reached 15 - save one more bit of data
// store the bit using a shift register: the hardware
// realization is simple compared to routing the bit
// dynamically, i.e. using received_data[bit_index]
received_data <= { in_sample, received_data[7:1] };
// manage the state transition
bit_index <= bit_index + 3'b1;
if (&bit_index) begin
// bit_index wraps around to zero
// sample_count wraps around to zero
state <= `STOP_BIT;
end
end
end
`STOP_BIT: begin
/*
* Accept the received data if input goes high:
*
* If stop signal condition(s) met, drive the {done} signal high
* for one bit cycle
*
* Otherwise drive the {err} signal high for one bit cycle
*
* Since this baud clock may not track the transmitter baud clock
* precisely in reality, accept the transition to handling the
* next start bit any time after the stop bit mid-point
*/
sample_count <= sample_count + 4'b1;
if (sample_count[3]) begin // reached 8 to 15
if (!in_sample) begin
// accept that transmit has completed only if the stop
// signal held for a time of >= 4 rx ticks before it
// changed to a start signal
if (sample_count == 4'b1000 &&
&in_prior_hold_reg) begin // meets the hold time
// can accept the transmitted data and output it
sample_count <= 4'b0;
out_hold_count <= 5'b1;
done <= 1'b1;
out <= received_data;
state <= `IDLE;
end else if (&sample_count) begin // reached 15
// bit did not go high or remain high -
// signal {err}, continuing until condition resolved
sample_count <= 4'b0;
received_data <= 8'b0;
busy <= 1'b0;
err <= 1'b1;
state <= `IDLE;
end
end else begin
if (&in_current_hold_reg) begin // meets min high hold time
// can accept the transmitted data and output it
sample_count <= 4'b0;
done <= 1'b1;
out <= received_data;
state <= `READY;
end else if (&sample_count) begin // reached 15
// did not meet min high hold time -
// signal {err} for this transmit
sample_count <= 4'b0;
err <= 1'b1;
state <= `READY;
end
end
end
end
`READY: begin
/*
* Wait one full bit cycle to sustain the {out} data, the
* {done} signal or the {err} signal
*/
sample_count <= sample_count + 4'b1;
if (!err && !in_sample || &sample_count) begin
// check if this is the change to a start signal -
// note that in this state, in_sample has met the min high
// hold time any time it drops to low
// (also in these cases, namely !{err} or tick 15 special case,
// signaling of {done} is in progress)
if (&sample_count) begin // reached 15, last tick, and no error
// (signaling of {done} is now complete)
if (in_sample) begin
// not transitioning to start bit -
// sample_count wraps around to zero
received_data <= 8'b0;
busy <= 1'b0;
end else begin
// transitioning to start bit -
// sustain the {busy} signal high
sample_count <= 4'b1;
end
done <= 1'b0;
out <= 8'b0;
state <= `IDLE;
end else begin
// in_sample drops from high to low
// (signaling of {done} continues)
sample_count <= 4'b1;
// continue the counting
out_hold_count <= sample_count + 5'b00010;
state <= `IDLE;
end
end else if (&sample_count[3:1]) begin // reached 14 -
// additional tick 15 comes from transiting the READY state
// to get to the RESET state
if (err || !in_sample) begin
state <= `RESET;
end
// otherwise, signaling of {done} is in progress (i.e. !{err}) -
// in this case, on tick 15, will be checking if in_sample
// dropped from high to low on the entry to IDLE state
end
end
default: begin
state <= `RESET;
end
endcase
end
endmodule