At the moment, internal lighting gains are only based on the input of fixed electrical lighting power per zone [W/m²] in the use conditions.
Why do we want to solve it?
In standards for usage boundary conditions of buildings (e.g. DIN V 18599-10, SIA 2024) only the illuminance level [lx = lm/m²] for specific zones is defined.
The electrical lighting power can then be determined using the lighting efficiency [lm/W] which depends on the used lighting device (halogen, LED, etc.)
How do we want to solve it?
Additional getter and setter methods are added in the useconditions.py class, so that the electrical lighting power per zone is determined by one of two options:
Fixed input of the electrical lighting power per zone in the use-conditions
Calculation of the electrical lighting power per zone by the input of an illuminance level and lighting efficienciy per zone in the use-conditions
By adding a boolean variable, it will be possible to switch between these two options.
Option 1) will be selected as default