EnergyPlus 8.8.0

26 Sep 13:29
Compare
Choose a tag to compare

EnergyPlus 8.8.0

The U.S. Department of Energy (DOE) has released EnergyPlus version 8.8.0. There were many bug fixes and prominent new features this release. The full changelog for this release cycle is listed below. For more information about EnergyPlus, please visit www.energyplus.net.

Platforms

  • Windows 7, 8 & 10: 32 and 64-bit versions
  • Linux (Ubuntu 14.04 and compatible) 64 bit versions; (RHEL-compatible versions may be available via Helpdesk)
  • Mac OSX 10.9 64 bit versions
  • EnergyPlus v8.8.0 has been developed and tested on all of these platforms

Changelog for EnergyPlus 8.8.0-94fe00376f

Consists of pull requests merged in since the last release - starting with SHA 78a111d

New Features

  • #5923 : Add tabular reporting capabilities inspired by Checksum report
  • #6087 : Enhanced Phase Change Material Simulation
  • #6103 : Enhance Proportional Demand Control Ventilation (DCV)
  • #6104 : Allow multiple solvers to find a root in HVAC system simulations
  • #6108 : Allow up to 10 speeds in UnitarySystemPerformance:Multispeed
  • #6114 : Glazing enhancements - input glazing properties as a function of incident angle
  • #6134 : Allow Min/Max Temperature control variable for OAReset SetPointManager
  • #6150 : Update LEED Summary Report
  • #6158 : Add user input for DX cooling coil low ambient temp cutout
  • #6179 : Add option to AvailabilityManager:NightCycle to run just until the zone temperature recovers #6151
  • #6188 : Enable Building Rotation, Movement, and a Water Boundary Condition
  • #6210 : Allow AirloopHVAC:ReturnPlenum to be used with Ideal Loads Air System
  • #6223 : Add DesignSpecification:OutdoorAir field and control to terminal units and fix DOA airflow distribution to ZoneHVAC units
  • #6227 : Improving Building Energy Simulation in an Urban Context
  • #6245 : Improved Airflow Calculations for BSDF window types
  • #6248 : Add air terminal unit sizing option, allow air loops with no return path, and partially allow multiple air loops serving the same zone
  • #6252 : Add a new field of Per Person Ventilation Rate Mode to AirTerminal:SingleDuct:Uncontrolled and AirTerminal:SingleDuct:Mixer
  • #6272 : Allow Multiple Air Loops to One Thermal Zone - Part 2 and Fix Zone Air Mass Balance
  • #6291 : IDF Editor - add new Duplicate Object and Change function and support new units
  • #6335 : Use local nodes for air flow network calculation

Performance Enhancements

  • #6083 : Only perform CTF calculations for constructions used by surfaces with CTF heat balance algorithm
  • #6253 : Move function calls with static arguments out of loops

Defects Repaired

  • #5723 : Variable speed coils can have higher flow rate than Packaged Terminal unit and fan
  • #5771 : Fixes inconsistent inlet and outlet air flow rates for FanCoil, Series PIU, EvapCooler, and HPWH
  • #5851 : Water heating coils do not honor system sizing input for heating capacity #5803
  • #6048 : DX coil calculation of bypass factor should use volume converted to standard mass
  • #6049 : Change reheat coil sizing to use air terminal unit air flow rate to size the water coil UA value.
  • #6056 : Add fixes to zone volume calcs including for non-convex zones
  • #6079 : PTAC hot water heating coil undersized for ventilation load
  • #6089 : Change HW coil UA sizing to use UA = 1 when loads are very small
  • #6090 : Adds SHA to the docs
  • #6096 : Fix integer division and duct radiative resistance calculations for AFN duct radiation object
  • #6101 : Refix new error message for Output:Table:Monthly and Annual don't have proper order for aggregation types
  • #6107 : Correct poor operation of water coils in UnitarySystems using set point control
  • #6116 : Correct surface convection calculation with AirRef = ZoneSupplyAirTemp and zero supply air flow in Window modules
  • #6120 : Fixed PTAC heating control problem when no heating load (issue #6095)
  • #6121 : Test that DX coil performance curves are near 1.0 at rated condition and VRF coils use terminal unit flow rate for sizing
  • #6123 : ZoneHVAC:Baseboard:RadiantConvective:Electric user-specified and design sizes are reporting the same value #5890
  • #6124 : Invalid Severe with CoolingTower:TwoSpeed when low speed autocalculated #5863
  • #6125 : Issue a severe error without AirflowNetwork model inputs when RoomAirModelType is AirflowNetwork
  • #6126 : Fix seemingly random sizing results problem related to AirloopHVAC:UnitarySystem with Fan:SystemModel
  • #6127 : Sizing:System with FlowPerCoolingCapacity and CoolingDesignCapacity not working as expected
  • #6133 : Corrected exhaust mass flow handling in CorrectZoneHumRat
  • #6137 : Fix four pipe beam crash when system sizing is off
  • #6139 : Fixed SolarCollector:UnglazedTranspired reporting for leaving air temperature when no flow
  • #6140 : Fix and clarify VAV minimum flow sizing, especially when VRP calculations adjust the min flow
  • #6142 : Fixed PlantLoop function IsNodeOnSetPtManager to allow any type of setpoint manager with common pipe
  • #6145 : DX coil system and unitary system with 100% OA coil mode and variable speed DX coils throws severe errors #6040
  • #6147 : Addressed missing component sizing output row in SQL database
  • #6162 : Fix EMS actuators for Zone Temperature Control
  • #6174 : Report an output variable of Surface Construction Index Output Variable
  • #6177 : Issue warnings for unbalanced outdoor and exhaust airflows in ZoneHVAC:OutdoorAirUnit
  • #6178 : Fix Advanced Single-Sided Natural Ventilation
  • #6181 : Cooling Panel UA Calculation Bug for Large Capacity/Low Water Flow Rate
  • #6184 : EarthTube Humidity Ratio Not Tracked Properly in Zone Moisture Balance
  • #6185 : Earth Tube One Per Zone Limit Error
  • #6191 : Fixed slat angle control and slat angle reporting issues for VB in equivalent layer window model
  • #6197 : Improved control of outdoor air system water coils
  • #6203 : Improve ZoneHVAC:UnitHeater operation when using multiple HVAC in the same zone
  • #6213 : Removed minimum limits of the minimum OA DB Temp for compressor operation input field #6190
  • #6216 : Fixed failing EnergyPlus unit test on develop #6215
  • #6217 : Pool Plant Loop Index Not Set for Second and Subsequent Pools in Input File
  • #6223 : Add DesignSpecification:OutdoorAir field and control to terminal units and fix DOA airflow distribution to ZoneHVAC units
  • #6226 : Calculated system load and single duct zone HVAC equipment load calculation uses different cp air values
  • #6232 : VRF fluid temperature control model crashes when using the Fan:SystemModel
  • #6235 : Fatal for High Cond Material for Finite Diff
  • #6236 : Correct ...
Read more

EnergyPlus 8.7.0

30 Mar 21:04
Compare
Choose a tag to compare

EnergyPlus 8.7.0

The U.S. Department of Energy (DOE) has released EnergyPlus version 8.7.0. There were many bug fixes and prominent new features this release. The full changelog for this release cycle is listed below. For more information about EnergyPlus, please visit www.energyplus.net.

Platforms

  • Windows 7 & 8: 32 and 64-bit versions
  • Linux (Ubuntu 14.04 and compatible) 64 bit versions; (RHEL-compatible versions may be available via Helpdesk)
  • Mac OSX 10.9 64 bit versions
  • EnergyPlus v8.7.0 has been developed and tested on all of these platforms

Changelog for EnergyPlus 8.7.0-78a111d

Consists of pull requests merged in since the last release - starting with SHA 198c6a3

New Features

  • #5705 : Modeling HVAC Operational Faults – Chiller Supply Water Temperature Sensor Offset
  • #5740 : Fill Plant Equipment Autosizing Gaps
  • #5766 : Modeling HVAC Operational Faults (1) Condenser Supply Water Temperature Sensor Offset (2) Cooling Tower Scaling
  • #5786 : Modeling HVAC Operational Faults – Coil Supply Air Temperature Sensor Offset
  • #5797 : Thermostat based on Adaptive Thermal Comfort Model
  • #5882 : Hybrid Zone Model
  • #5901 : Add Kiva foundation heat transfer calculations
  • #5924 : Allow polygonal windows in AirflowNetwork
  • #5928 : Add EIO tables to new Tabular summary report
  • #5929 : Hybrid Ventilation Controls with CO2 and Adaptive Temperatures plus new Minimum Operation Time
  • #5943 : Variable Speed DX Coil Enhancements
  • #5947 : Add the latest LCC fuel escalation factors from NIST 2016
  • #5957 : Connect Zone HVAC Unit Ventilator to DOA
  • #5970 : Simple Tower Autosizing 25.6C inlet WB does not comply with 90.1-G #5020
  • #5976 : Allowed SetpointManager:Coldest to work with single-duct systems
  • #5983 : Water coil autosizing expanded to allow specifying design water temperature difference separately for each coil
  • #5988 : Add Adaptive Thermal Comfort Thermostat Control
  • #5989 : Fault Modeling for Fouling of Boilers, Chillers, and Evaporative Coolers
  • #5994 : New feature - ASHRAE 90.1 SZVAV control for Unitary Systems
  • #6000 : Revise plant and condenser loop volume autocalculate and add new field for loop circulation time
  • #6011 : Allow Use of Curves and Tables for Wind Pressure Coefficient Profiles
  • #6014 : New fan input object Fan:SystemModel
  • #6017 : Allow regular expressions as keys for Output:Variable
  • #6021 : AFN Duct Radiation
  • #6045 : IDF Editor add validation check option, multiple object delete and duplicate, fix Schedule:TypeLimits case sensitive

Performance Enhancements

  • #6018 : Update SQLite library

Defects Repaired

  • #5718 : Fix errors in energy+idd
  • #5727 : Add missing lists of valid object type/name in AirLoopHVAC:OutdoorAirSystem:EquipmentList, Branch, PlantEquipmentList, CondenserEquipmentList objects
  • #5740 : Fill Plant Equipment Autosizing Gaps
  • #5855 : Fan Coil control may fail when used with DOAS as inlet to fan coil
  • #5902 : Fix ConvertESOMTR when ESO data dictionary not ended properly
  • #5918 : Fix parallel fan-powered induction unit zone fan controls
  • #5920 : Processing of non-rectangular window surfaces
  • #5928 : Add EIO tables to new Tabular summary report
  • #5937 : Fix Help menu in EP-Launch to align with PDF file names
  • #5940 : Coil:Heating:Fuel changed to accept Propane
  • #5942 : Add warning when Meter:Custom references another Meter:Custom
  • #5945 : Fix daylighting table columns in lighting summary report
  • #5946 : VRF terminal unit PLR limit warnings under low heating loads
  • #5947 : Add the latest LCC fuel escalation factors from NIST 2016
  • #5951 : Fix Output:Table:Annual references to schedules not showing name in column heading
  • #5955 : #5697 Economizer with preheat bringing in excess OA
  • #5960 : 5958 - Correct indexing of ElecRadSys and SurfaceGroup objects
  • #5967 : ObjexxFCL minor update to correct public visibility of protected methods and data
  • #5973 : Hot water preheat coil now runs when economizing
  • #5978 : Order of setpoint managers can cause fatal missing setpoint error for Controller:WaterCoil controlling
  • #5979 : Zone-level equipment output may not match system outputs when there is significant thermostat setpoint change
  • #5980 : EMPD R-coating bugfix
  • #5981 : Ecoroof Material:RoofVegetation fails with NANs if the input value for initial moisture is greater than max moisture
  • #5986 : Changed Fuel Type field as required in Coil:Cooling:DX:MultiSpeed and…
  • #5990 : People object changed to no longer require fields not needed for adaptive comfort models
  • #5992 : Autosizing of heating coil UA failed for Coil:Heating:Water for plant loop exit temperature below 45C #5638
  • #5993 : Prevent crash in ZoneHVAC:LowTemperatureRadiant:* when the system is heat-only or cool-only
  • #5996 : Addressed documentation Issues - October-December 2016 #5896
  • #6000 : Revise plant and condenser loop volume autocalculate and add new field for loop circulation time
  • #6002 : Initialization output cleanup - eio output and table output
  • #6003 : AirToAir Heat Pump Maximum Supply Air Temperature Not Working
  • #6008 : Report correct outputs of AFN Surface Venting Window or Door Opening …
  • #6012 : Constant COP chiller sizing is broken and leads to zero chiller energy consumption #6010
  • #6024 : Corrects multispeed DX cooling coil RH>100 issue
  • #6026 : Corrected surface convection calculation with AirRef ZoneSupplyAirTemp
  • #6034 : Improved sizing for Coil:Cooling:DX bypass factor
  • #6035 : Coil:*:WaterToAirHeatPump:EquationFit show unreasonable low/high outlet water temperatures
  • #6038 : Facility Electric output variables do not show in rdd file
  • #6041 : Terminal unit reheat coils size to zero when zone has no design heating load #6006
  • #6045 : IDF Editor add validation check option, multiple object delete and duplicate, fix Schedule:TypeLimits case sensitive
  • #6054 : Correct surface convection calculation with AirRef = ZoneSupplyAirTemp with zero supply flow
  • #6057 : Autosized nominal capacity and design water flow rate are set to hard sized values for Hot Water Boilers #6053
  • #6060 : Heating only AirloopHVAC:UnitarySystem crashes during sizing for DX multispeed heating coil
  • #6065 : GroundHeatExchanger:Slinky plant initialization corrected, fix severe error
  • #6066 : Fix initialization issue in OutputProcessor related to reporting frequency
  • [#6067](https://github.com/NRE...
Read more

Test build for testing of ReverseDD and AnnualSimulation targets

13 Mar 05:03
Compare
Choose a tag to compare
v8.7.0-ReleaseTestingEnhancements-3

Clean up cmake build flags for ReverseDD and AnnualSim

EnergyPlus 8.6.0

27 Sep 15:49
Compare
Choose a tag to compare

EnergyPlus 8.6.0

Windows packages for EnergyPlus 8.6.0 and prior had a vulnerability in the View3D binary that could expose users to a stack-based buffer overflow. Because of this, all Windows packages 8.6.0 and older have been purged and are no longer available. We apologize for any inconvenience.

The U.S. Department of Energy (DOE) has released EnergyPlus version 8.6.0. The focus of this release was predominantly on bug fixes and code robustness, though some priority new features did get implemented. The full changelog for this release cycle is listed below. For more information about EnergyPlus, please visit www.energyplus.net.

Platforms

  • Windows 7 & 8: 32 and 64-bit versions
  • Linux (Ubuntu 14.04 and compatible) 64 bit versions; (RHEL-compatible versions may be available via Helpdesk)
  • Mac OSX 10.9 64 bit versions
  • EnergyPlus v8.6.0 has been developed and tested on all of these platforms

Changelog for EnergyPlus 8.6.0-69631fe028

Consists of pull requests merged in since the last release - starting with SHA c87e61b

New Features

  • #5027 : New simple chilled water cooling panel
  • #5093 : Improved Effective Moisture Penetration Depth model
  • #5584 : Add Air Source Integrated Heat Pump and Fix Variable Speed Heat Pump Water Heater COP Bug
  • #5588 : Adds underground column to the Zone Summary table in IVRS
  • #5633 : Add Heat Recovery Capability for Variable Refrigerant Flow Simulations
  • #5634 : Add AirflowNetwork zone pressure control
  • #5646 : Intelligent Defaults for Minimum Flow Fraction on VAV Terminals
  • #5676 : Connect DOAS to more ZoneHVAC Equipment - PTAC, PTHP, VRF, and UnitarySystem
  • #5677 : Provided Crankcase heater outputs for Coil:Cooling:DX:MultiSpeed
  • #5698 : Allow ZoneCrossMixing to be used in overlapping zones and revise some mixing output variables
  • #5725 : More Daylighting Control Sensors/Integrate DElight
  • #5746 : Add an optional fuel type to OtherEquipment
  • #5809 : Add Heating Coil that can handle other fuel types
  • #5824 : Nightcycle manager new control types and zone lists
  • #5867 : EP-Launch-Lite (v2.0)

Performance Enhancements

  • #5776 : Improve ESO file write speed

Defects Repaired

  • #5312 : Fixed bug that showed opaque window when solar reflectance was zero.
  • #5485 : Stratified Tank Optimizations
  • #5561 : Fixed NAN causing fatal error due to negative velocity in CrossVentilation RoomAirModel
  • #5572 : Fixed the degree day bases used with the LEED and Climatic summaries
  • #5575 : Removing Deprecated Fields from Several Objects
  • #5580 : LEED Summary EAp2-4/5 report row shown in uppercase and document special end-use subcategory tags
  • #5582 : Remove OA flow rate dependency on Branch Maximum Flow Rate and deprecate the field
  • #5584 : Add Air Source Integrated Heat Pump and Fix Variable Speed Heat Pump Water Heater COP Bug
  • #5590 : Fully autosized version of 5ZoneWLHPPlantLoopTower runs very slow
  • #5593 : Address issue #5126 and a bug in the ExternalInterface
  • #5594 : Update life cycle cost tables to handle water utility tariff costs correctly
  • #5598 : Removed automatic reporting of tariff and lifecycle reports now they need to be explicitly requested.
  • #5609 : Fix air cooled absorption chiller heaters
  • #5615 : Fix LaTeX page numbers
  • #5616 : Add support for JtokWH conversion in leed table
  • #5621 : Documentation Fixups
  • #5624 : Correct crash with only single node reference in input check CheckNod…
  • #5632 : Correct ZoneHVAC system air flow rate to be the same as variable speed DX coil air flow to eliminate flow imbalance warnings
  • #5639 : Add rows for district heating and cooling virtual rate in LEED EAp2-3
  • #5642 : SPMs with same reference and set point node name should fatal
  • #5643 : Restore "Advanced Surface Concepts" in Eng Ref + Correct Display Equations that should be Inline
  • #5645 : Updated documentation on RunMultiDir.bat
  • #5647 : Fix various documentation bugs: equation delimitation, missing figure, missing table
  • #5649 : Put references to DOE2 BLAST and ParametricSpreadsheets in docs
  • #5651 : Added EMS On/Off Supervisory control for air loop water coils
  • #5652 : Fix to add opening area for windows to IVRS report.
  • #5654 : Fixing several NANs found in user file related to storage tanks
  • #5658 : Allowed venting availability to control openings with control mode ASHRAE55Adaptive or CEN15251Adaptive
  • #5660 : Trap uninitialized EMS variables and math failures, and warn for unused actuators
  • #5666 : Output:EnergyManagementSystem now creates .edd file
  • #5669 : Fix conversion of unitless variables to IP in tabular output and added missing conversions
  • #5670 : Fixed NAN problem with a horizontal door as a floor sub-surface in displacement ventilation room air model
  • #5671 : Use tighter limits on FCU water flow rate if RegulaFalsi iteration limit is exceeded
  • #5674 : Fix hang when using malformed Table:TwoIndependentVariables
  • #5678 : Fix array bound mismatch with transitioning 8.1 to 8.2 for ZoneHVAC:UnitHeater
  • #5680 : Fix WeatherProperty:SkyTemperature with weather file with small time intervals
  • #5690 : Replace missing EMS in example file LrgOff_GridStorageEMSSmoothing
  • #5691 : Corrections to WaterToAirHeatPump (WSHP) water flow control
  • #5694 : Fixed constant flow radiant heat not operating when it should
  • #5701 : Changes interpolation for wind direction when to do it properly around 0 degrees
  • #5702 : Provide warning for DX heating coil when DefrostEIR performance curve name is blank and defrost method is reverse cycle
  • #5703 : Correct OA controller mixed air node set point calculation to allow values <0
  • #5707 : #4110 Correct Reverse Design Day testing so that results are identical
  • #5708 : Fixed incorrect array indices in ZoneMassConservation object report variables
  • #5709 : Fixed NaN in heat balance due to not enclosed space
  • #5713 : Fix memory allocation bug in FMI libraries.
  • #5715 : #5524 ZoneHVAC:OutdoorAirUnit reported fan power and energy corrected with exhaust fan
  • #5716 : Eliminate warning for zones with <6 surfaces and improve warning for <4 surfaces
  • #5717 : Added support for tool coupling.
  • #5719 : Tables of One and Two Independent Variables do not allow extrapolation when appropriate
  • #5721 : Airflow network distribution outputs for node pressure and flow now report zero when the distribution system is off
  • #5724 : Correct UnitarySystem and Multispeed Heat Pump heat recovery calculation to honor maximum outlet temperature
  • #5731 : Detect interior movable insulation used with internal source/sink...
Read more

Test the installed log-version of NSIS

02 Feb 20:58
Compare
Choose a tag to compare
Pre-release
NSISLogTest1

Add logging when registering a DLL/OCX does not work.

EnergyPlus 8.5.0

25 Mar 19:05
Compare
Choose a tag to compare

EnergyPlus 8.5.0

Windows packages for EnergyPlus 8.6.0 and prior had a vulnerability in the View3D binary that could expose users to a stack-based buffer overflow. Because of this, all Windows packages 8.6.0 and older have been purged and are no longer available. We apologize for any inconvenience.

The U.S. Department of Energy (DOE) has released EnergyPlus version 8.5.0. The focus of this release was predominantly on bug fixes and code robustness, though some priority new features did get implemented. The full changelog for this release cycle is listed below. For more information about EnergyPlus, please visit www.energyplus.net.

Interface Note

As with every EnergyPlus, older versions of EnergyPlus input files will not run directly with this version, and must be transitioned up to the latest version. EnergyPlus is packaged with transition utilities for updating the idfs automatically. There is also a Rules spreadsheet available in the installation to help interface developers program the transition. We are also tracking the structural changes to the outputs for EnergyPlus and including this documentation in the installer. For 8.5.0, the input rules changes file is here and the output rules changes file is here.

Documentation

The EnergyPlus documentation underwent a full transition from the Markdown/MathJax/HTML basis, to a full LaTeX implementation. This helped drastically streamline the development process and improve the developer's ability to test documentation changes, and also produced much improved pdf documentation over the last couple versions. The conversion was tested several times and confirmed to produce the same content as before to as best as we could tell. However, if you find any structural issues (pieces missing...), please post an issue on GitHub. We are going to be making our way through the entire set of documentation, cleaning up visual issues like alignment or long equations, so no need to post an issue for those visual things. We'll also be styling the documentation up to make it easy on the eyes.

Platforms

  • Windows 7 & 8: 32 and 64-bit versions
  • Linux (Ubuntu 14.04 and compatible) 64 bit versions; (32-bit and RHEL-compatible versions may be available via Helpdesk)
  • Mac OSX 10.9 64 bit versions
  • EnergyPlus v8.5.0 has been developed and tested on all of these platforms

Changelog for EnergyPlus 8.5.0-c87e61b44b

Consists of pull requests merged in since the last release - starting with SHA 832e4bb

New Features

  • #5256 : For multiple year run periods, only show final simulation year in tabular reports
  • #5267 : Improve reheat coil sizing when there is no central heating coil
  • #5281 : Improved Scalable Pump Sizing
  • #5293 : Add new output variables for ZoneHVAC:IdealLoadsAirSystem supply and outdoor air flow rates
  • #5297 : Add conduction finite difference node heat flux output
  • #5308 : Add output for node specific heat
  • #5375 : Improved economizer integration and single mode option for multi-speed coils
  • #5392 : Add HeatExchanger:AirToAir:SensibleAndLatent as a valid air loop main branch component
  • #5411 : Add net area column to envelope summary
  • #5437 : Electric storage controls and clean up
  • #5477 : Add Humidifier as valid component to OA subsystem
  • #5493 : Add new ASHRAE single-zone VAV fan control for fan coil units
  • #5522 : Add LCCusePriceEscalationDataSet2015 dataset
  • #5542 : Shiny LaTeX Documentation

Performance Enhancements

  • #5226 : ObjexxFCL vector-like API extensions
  • #5347 : ObjexxFCL update
  • #5395 : ObjexxFCL 4.1
  • #5399 : Octree system with initial application to daylighting

Defects Repaired

  • #5099 : Fix calculation of window frame heat gain
  • #5159 : Remove airloop flow reset which can cause max iteration errors and fix AirTerminal:SingleDuct:VAV schedule logic
  • #5175 : Fix daylighting shape test for isosceles trapezoid surfaces which were incorrectly marked as rectangular
  • #5208 : Updating IDD and error handling for GHX:Vertical
  • #5209 : AirloopHVAC:UnitarySystem heating only systems incorrectly size flow rate when using FlowPerHeatingCapacity method
  • #5216 : Disable VentilationRateProcedure sizing for systems sized to VentilationRequirement and fix zone multipliers in OA summary report
  • #5271 : Heat Pump Water Heater Energy Balance Bugfix
  • #5275 : Allow SetpointManager:OutdoorAirReset to work with positive or negative slope
  • #5283 : Correct ground temperature model index for Site:GroundDomain:Basement
  • #5289 : Improved flushing of output per line
  • #5290 : Revise memory allocation in FMU import libraries
  • #5291 : Fix EMS actuators for dual temperature setpoints
  • #5292 : Fix invalid IDD and IDF version warnings in input processor
  • #5295 : Improve TimeBins report rounding
  • #5300 : Add ElectricStorage end-use to fix misplaced storage in ABUPS Electric Loads Satisfied table
  • #5304 : Fix uninitialized variables found by address santizer
  • #5305 : Fix SingleSpeedFluidCooler GetInput autosize checking
  • #5307 : Fix calculation of node RH, wetbulb, and dewpoint for EMS sensors if not also requested as an output variable
  • #5309 : Add RegisterPlantCompDesignFlow for Refrigeration:Condenser:WaterCooled
  • #5315 : Fix RoomAirNode AirflowNetwork InternalGains IDD metadata
  • #5322 : Fix transition crash when shading:zone:detailed has a blank number vertices
  • #5323 : Update missing GroundDomain output variables and documentation
  • #5324 : Water Main correlation fix for southern latitudes
  • #5326 : Update slab and basement output variable names
  • #5327 : Fixed total number of hours not met by adding variable reset
  • #5331 : Fix crash when assigning 2 unitary system to same zone
  • #5333 : Plant heat exchanger dual deadband control fixed to run when beneficial
  • #5336 : Correct humidity controls for dehumidification - Contoller:WaterCoil and SetpointManager:SingleZone:Humidity:Maximum
  • #5337 : Resolve OA system temps when HX is in OA equipment list
  • #5338 : Add error check for zone nodes being used more than once
  • #5339 : Removed SecZoneAirNodeNum so no need to register that node.
  • #5340 : EnergyPlus to FMU (ExternalInterface) Header File Updates
  • #5342 : Improve warning message when coil heating water sizes to zero
  • #5345 : More robust check for subsurface facing angle vs base surface
  • #5348 : Correct issues with EMS parsing of negative numbers
  • #5350 : Missing commas in write statements fixed
  • #5352 : Various documentation and IDD updates
  • #5358 : Perturb SHR if bypass factor calculation appears to fail
  • #5361 : Add autosize to Chiller:Absorption:Indirect flow rate fields
  • #5367 : Add outdoor air mixer in terminal unit of the VRF-FluidTCtrl model
  • #5369 : Fix to an allocate used in the Zone Component Loads report
  • [#5371](https://github.com/NREL/EnergyPlus/pull/...
Read more

EnergyPlus 8.4.0 Update 1

04 Jan 18:15
Compare
Choose a tag to compare

The U.S. Department of Energy (DOE) has released EnergyPlus version 8.4.0. New feature highlights and bug fixes are listed below. For more information about EnergyPlus, please visit www.energyplus.net.

Windows packages for EnergyPlus 8.6.0 and prior had a vulnerability in the View3D binary that could expose users to a stack-based buffer overflow. Because of this, all Windows packages 8.6.0 and older have been purged and are no longer available. We apologize for any inconvenience.

This is Update 1 of EnergyPlus version 8.4.0 which includes important bug fixes.

ChangeLog (since the version 8.3.0 release)

New Features

  • #4698 : Residential Heat Pump Water Heater Improvements
  • #4752 : New Variable Speed Heat Pump Water Heater Model
  • #4849 : Implement capability for DX coils to transfer condenser heat to a zone
  • #4869 : Convert EnergyPlus Documentation to a Markdown Basis
  • #4881 : Update Life cycle costing data set files for 2013 and 2014
  • #4894 : Add Fault Simulation for Dirty Air Filters
  • #4909 : Implement return water reset setpoint manager
  • #4913 : Add HotWater preheat coil as valid type in HVACTemplate systems
  • #4940 : Add autosizing to HR units, Evap coolers, Elec baseboard, dehumidifiers, and wwhp
  • #5002 : Allow accounting for direct-to-zone DOAS on zone sizing.
  • #5010 : Add New DemandManager:Ventilation Capabilities
  • #5017 : Add PlantEquipmentOperation:ThermalEnergyStorage controls
  • #5026 : New VRF Heat Pump Model
  • #5068 : Additional Water to Air Heat Pump Example Files
  • #5081 : Room airflow network
  • #5088 : Add Multiple Tower Support in Condenser Entering Temp Reset Setpoint Managers
  • #5091 : Added multi-speed fan use with 4Pipe Fancoil unit and water coils in Unitary System
  • #5107 : Fill some gaps in HVAC component configuration support
  • #5123 : Link Infiltration to HVAC Operation and Add Return Air Flow Controls
  • #5129 : Four pipe beam air terminal
  • #5131 : Add CO2-based Proportional Demand Controlled Ventilation Based on Design Occupancy
  • #5152 : Improving Ground Temperature Models
  • #5154 : Add new report object: Output:Table:Annual
  • #5220 : Added component matrix to IO Ref.
  • #5256 : Tabular reports show only last year in multiple year run period.
  • #5293 : Add new output variables for ZoneHVAC:IdealLoadsAirSystem supply and outdoor air flow rates
  • #5297 : Add conduction finite difference node heat flux output
  • #5308 : Add output for node specific heat

Performance Enhancements

  • #4843 : Updates to ObjexxFCL and 2+D arrays for row-major
  • #4928 : ObjexxFCL Array grow-friendly API and reverse iterator extensions/fixups
  • #4938 : Minor performance tweaks
  • #5008 : DaylightingManager performance refactoring
  • #5049 : Update SQLite library to 3.8.11
  • #5066 : WindowComplexManager+ performance tuning
  • #5151 : Performance tweaks and a few bug fixes contributed by Autodesk and an ObjexxFCL update
  • #5226 : ObjexxFCL vector-like API extensions
  • #5347 : ObjexxFCL update

Defects Repaired

  • #4797 : Trap invalid ZoneMixer name in AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction
  • #4800 : Corrected arguments for scheduled solar gain function in complex glazing surface
  • #4833 : Allow HX to control to set point temperature regardless of operating mode
  • #4872 : Fix issues with previous version transition tools
  • #4879 : Addresses #4662 SetupEMSActuator is missing duplicates.
  • #4880 : Fix various typos and other minor edits in documentation only
  • #4885 : Fix typos in LowTemperatureRadiant sizing messages
  • #4892 : Fix HVACTemplate:System:ConstantVolume preheat, economizer, and setpoint manager problems
  • #4896 : Fix high speed UA autosizing fatal error for FluidCooler:TwoSpeed
  • #4897 : Address the water-source-heat-pump SHR greater than 1 issue
  • #4908 : Revised IO Ref on VRF condenser Rated Heating Capacity Sizing Ratio
  • #4917 : HVACTemplate clean up initial schedules and schedule type
  • #4918 : Improve chilled water storage tank deadband control
  • #4920 : Fix Electric EIR Chiller model delivering chilled water when off
  • #4930 : HVACTemplate - remove old plant loop load distribution types
  • #4937 : Clarify HVAC Sizing Summary report headings, footnotes and documentation
  • #4949 : Update IDD note for VRF systems
  • #4966 : Fixes out-of-order IDD numbering on inputs for slinky GHX
  • #4981 : Fixed ABUPS report row total for water and corrected checksum error message
  • #4990 : Address documentation issues in 4906
  • #4998 : Fix bugs in sqlite timeseries output and add IDF parsing capabilities within unit tests
  • #5005 : Add Transition Rules for HVACTemplate Plant Loop Objects
  • #5009 : Initialize plenum induced air node conditions fix 4926
  • #5012 : Reset design outlet humidity ratio when entering humidity ratio is less to prevent SHR>1 in DX coil sizing
  • #5019 : Fix ZoneHVAC:VentilatedSlab fan power and output reporting
  • #5023 : Fix humidifier bug issue #4992
  • #5024 : Fixed OutdoorDryBulbTemperature Gradient and added unit test from 5014
  • #5025 : 4973 heatpump defrost bug
  • #5028 : SwimmingPool:Indoor Maximum Water Flow Rate Input and Output Corrected to be Volume Instead of Mass
  • #5038 : Fix non-legacy prefix for sqlite error files.
  • #5043 : fixing vshpwh stratified tank bug
  • #5047 : Misc Documention Fixes
  • #5059 : Fix search for ReadVarsESO in installed package directory structure.
  • #5065 : Various documentation fixes (#4956 #4997)
  • #5071 : Fix broken links in documentation
  • #5072 : Reset variables at end of warmup
  • #5078 : Added SwimmingPool Floor object list in IDD
  • #5080 : Fix writing to input processing error file (*.iperr) when using the CLI
  • #5082 : Fix for attempts to write output to a directory without permissions
  • #5084 : Corrected False EMS Sensor Error
  • #5090 : Add Missing evapotranspiration parameter in PipingSystem:Underground:Domain Docs
  • #5096 : Clean out non-ascii characters in source code and test files
  • #5097 : Cleanup bad 8.2 to 8.3 transition comments for slab object
  • #5100 : Fix naming issues in ground domain doc...
Read more

EnergyPlus 8.4.0

30 Sep 14:58
Compare
Choose a tag to compare

This is the public release of EnergyPlus 8.4.0.

Windows packages for EnergyPlus 8.6.0 and prior had a vulnerability in the View3D binary that could expose users to a stack-based buffer overflow. Because of this, all Windows packages 8.6.0 and older have been purged and are no longer available. We apologize for any inconvenience.

Changes for this version:

New Features

  • #4698 : Residential Heat Pump Water Heater Improvements
  • #4752 : New Variable Speed Heat Pump Water Heater Model
  • #4849 : Implement capability for DX coils to transfer condenser heat to a zone
  • #4869 : Convert EnergyPlus Documentation to a Markdown Basis
  • #4881 : Update Life cycle costing data set files for 2013 and 2014
  • #4894 : Add Fault Simulation for Dirty Air Filters
  • #4909 : Implement return water reset setpoint manager
  • #4913 : Add HotWater preheat coil as valid type in HVACTemplate systems
  • #4940 : Add autosizing to HR units, Evap coolers, Elec baseboard, dehumidifiers, and wwhp
  • #5002 : Allow accounting for direct-to-zone DOAS on zone sizing.
  • #5010 : Add New DemandManager:Ventilation Capabilities
  • #5017 : Add PlantEquipmentOperation:ThermalEnergyStorage controls
  • #5026 : New VRF Heat Pump Model
  • #5068 : Additional Water to Air Heat Pump Example Files
  • #5081 : Room airflow network
  • #5088 : Add Multiple Tower Support in Condenser Entering Temp Reset Setpoint Managers
  • #5091 : Added multi-speed fan use with 4Pipe Fancoil unit and water coils in Unitary System
  • #5107 : Fill some gaps in HVAC component configuration support
  • #5123 : Link Infiltration to HVAC Operation and Add Return Air Flow Controls
  • #5129 : Four pipe beam air terminal
  • #5131 : Add CO2-based Proportional Demand Controlled Ventilation Based on Design Occupancy
  • #5152 : Improving Ground Temperature Models
  • #5154 : Add new report object: Output:Table:Annual
  • #5220 : Added component matrix to IO Ref.

Performance Enhancements

  • #4843 : Updates to ObjexxFCL and 2+D arrays for row-major
  • #4928 : ObjexxFCL Array grow-friendly API and reverse iterator extensions/fixups
  • #4938 : Minor performance tweaks
  • #5008 : DaylightingManager performance refactoring
  • #5049 : Update SQLite library to 3.8.11
  • #5066 : WindowComplexManager+ performance tuning
  • #5151 : Performance tweaks and a few bug fixes contributed by Autodesk and an ObjexxFCL update

Defects Repaired

  • #4797 : Trap invalid ZoneMixer name in AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction
  • #4800 : Corrected arguments for scheduled solar gain function in complex glazing surface
  • #4833 : Allow HX to control to set point temperature regardless of operating mode
  • #4872 : Fix issues with previous version transition tools
  • #4879 : Addresses #4662 SetupEMSActuator is missing duplicates.
  • #4880 : Fix various typos and other minor edits in documentation only
  • #4885 : Fix typos in LowTemperatureRadiant sizing messages
  • #4892 : Fix HVACTemplate:System:ConstantVolume preheat, economizer, and setpoint manager problems
  • #4896 : Fix high speed UA autosizing fatal error for FluidCooler:TwoSpeed
  • #4897 : Address the water-source-heat-pump SHR greater than 1 issue
  • #4908 : Revised IO Ref on VRF condenser Rated Heating Capacity Sizing Ratio
  • #4917 : HVACTemplate clean up initial schedules and schedule type
  • #4918 : Improve chilled water storage tank deadband control
  • #4920 : Fix Electric EIR Chiller model delivering chilled water when off
  • #4930 : HVACTemplate - remove old plant loop load distribution types
  • #4937 : Clarify HVAC Sizing Summary report headings, footnotes and documentation
  • #4949 : Update IDD note for VRF systems
  • #4966 : Fixes out-of-order IDD numbering on inputs for slinky GHX
  • #4981 : Fixed ABUPS report row total for water and corrected checksum error message
  • #4990 : Address documentation issues in 4906
  • #4998 : Fix bugs in sqlite timeseries output and add IDF parsing capabilities within unit tests
  • #5005 : Add Transition Rules for HVACTemplate Plant Loop Objects
  • #5009 : Initialize plenum induced air node conditions fix 4926
  • #5012 : Reset design outlet humidity ratio when entering humidity ratio is less to prevent SHR>1 in DX coil sizing
  • #5019 : Fix ZoneHVAC:VentilatedSlab fan power and output reporting
  • #5023 : Fix humidifier bug issue #4992
  • #5024 : Fixed OutdoorDryBulbTemperature Gradient and added unit test from 5014
  • #5025 : 4973 heatpump defrost bug
  • #5028 : SwimmingPool:Indoor Maximum Water Flow Rate Input and Output Corrected to be Volume Instead of Mass
  • #5038 : Fix non-legacy prefix for sqlite error files.
  • #5043 : fixing vshpwh stratified tank bug
  • #5047 : Misc Documention Fixes
  • #5059 : Fix search for ReadVarsESO in installed package directory structure.
  • #5065 : Various documentation fixes (#4956 #4997)
  • #5071 : Fix broken links in documentation
  • #5072 : Reset variables at end of warmup
  • #5078 : Added SwimmingPool Floor object list in IDD
  • #5080 : Fix writing to input processing error file (*.iperr) when using the CLI
  • #5082 : Fix for attempts to write output to a directory without permissions
  • #5084 : Corrected False EMS Sensor Error
  • #5090 : Add Missing evapotranspiration parameter in PipingSystem:Underground:Domain Docs
  • #5096 : Clean out non-ascii characters in source code and test files
  • #5097 : Cleanup bad 8.2 to 8.3 transition comments for slab object
  • #5100 : Fix naming issues in ground domain documentation
  • #5102 : Fix AirflowNerwork Error Output to Report Missing Zone
  • #5103 : Fixed Capitalization Errors in IDD
  • #5106 : ExpandObjects support on Linux command line
  • #5114 : Corrected leap year adjustments in scheduled values for WeatherProperty:SkyTemperature
  • #5116 : Using sea level atmospheric pressure for HPWH ratings
  • #5117 : Fix evaporator condenser pump autosizing
  • #5124 : HPWH Equipment Sequence Number Error to Warning
  • #5132 : Fix to Wrapped Condenser HPWH connections to coil when there is mo...
Read more

v8.3.3

22 Jun 15:21
Compare
Choose a tag to compare
v8.3.3 Pre-release
Pre-release

6/17/2015 Iteration Build

v8.3.2

26 May 19:12
Compare
Choose a tag to compare
v8.3.2 Pre-release
Pre-release

5/20/2015 Iteration Build